down.

9.15 Follow me function

9.15.1 This function starts when the indoor unit received the signal from remote controller, and the air
conditioner is operated by the temperature information included in the signal and the set temperature.
In this mode, the indoor temperature sensor in the indoor unit is inactive.
9.15.2 When the indoor unit received the signal by pressing the button of remote controller, the buzzer
in indoor unit will sound once. And the remote controller will send the corrected signal automatic per 3
minutes, the buzzer keep quiet at this time.
9.15.3 When the indoor unit have not received the corrected signal for 7 minutes, this function will be
shut down. The air conditioner is working in common way.

9.16 Self-clean function

9.16.1 This function is available only under COOLING (including AUTO and FORCE cooling mode) or
DRY mode, no matter it's cooling only or cooling & heating model.
9.16.2 For cooling only models, the air conditioner will operate under FAN ONLY mode at LOW fan
speed for 30 minutes, and then stop the operation and the unit turn off.
9.16.3 For cooling & heating models, the air conditioner will operate: FAN ONLY mode at Low fan
speed(13 minutes)--Heating operation with LOW fan speed (1 minute)---FAN ONLY operation(2
minutes)--Stop Operation---Turn off the unit.
9.16.4 Once the Auto Clean function is activated, all TIMER setting will be cancelled.
9.16.5 This operation will be stopped only by press the AUTO CLEAN button on remote controller again
or the OFF button, then the unit will turn off.
9.16.6 During Cleaning operation, only the on/off, auto clean, swing, air direction, clear air and LED
display buttons are available.

9.17 Turbo

9.17.1 Under cooling mode (except Force Cooling mode), the indoor fan motor will run in Turbo speed
when receive the signal from remoter controller, and will get back to the presetting speed when receive
again.
9.17.2 The turbo mode will cancel and indoor fan motor will get back to the presetting speed when one
of following condition occur:
a. mode changed;
b. get into Force Cooling mode;
c. turn off the air conditioner;
9.17.3 Sleep mode is not available in this mode.