Installation manual
Daikin Altherma low temperature monobloc
EBLQ05CAV3
EBLQ07CAV3
Installation manual
EDLQ05CAV3
English
Daikin Altherma low temperature monobloc
EDLQ07CAV3

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Altherma EBLQ07CAV3 and is the answer not in the manual?

Questions and answers

Summary of Contents for Daikin Altherma EBLQ07CAV3

  • Page 1 Installation manual Daikin Altherma low temperature monobloc EBLQ05CAV3 EBLQ07CAV3 Installation manual EDLQ05CAV3 English Daikin Altherma low temperature monobloc EDLQ07CAV3...
  • Page 2 3P403988-1E...
  • Page 3: Table Of Contents

    5.2.7 Contact/helpdesk number ........... 16 Daikin website (publicly accessible). Menu structure: Overview installer settings....... 17 ▪ The full set of latest technical data is available on the Daikin extranet (authentication required). 6 Commissioning Checklist before commissioning..........18 Checklist during commissioning ..........18 About the box 6.2.1...
  • Page 4: Preparation

    See the installer reference guide for more information. (mm) (mm) Air outlet Minimum required flow rate Air inlet 05+07 models 12 l/min See the recommended procedure as described in "6.2  Checklist during commissioning" on page 18. Installation manual EBLQ+EDLQ05+07CAV3 Daikin Altherma low temperature monobloc 4P403578-1F – 2018.06...
  • Page 5: Preparing Electrical Wiring

    The maximum height of the upper protruding part of the Installation bolts is 15 mm. Opening the units 4.1.1 To open the outdoor unit DANGER: RISK OF ELECTROCUTION DANGER: RISK OF BURNING EBLQ+EDLQ05+07CAV3 Installation manual Daikin Altherma low temperature monobloc 4P403578-1F – 2018.06...
  • Page 6: To Install The Outdoor Unit

    It is possible to install the unit on brackets to the wall: 4.2.2 To install the outdoor unit CAUTION Do NOT remove the protective cardboard before the unit is installed properly. Installation manual EBLQ+EDLQ05+07CAV3 Daikin Altherma low temperature monobloc 4P403578-1F – 2018.06...
  • Page 7: To Provide Drainage

    3 Insert a rubber sheet between the cables and the outdoor unit to prevent the cables from scratching the paint (field supply). 4 Attach the ends of the cables and tighten them. Protective cardboard Instruction sheet EBLQ+EDLQ05+07CAV3 Installation manual Daikin Altherma low temperature monobloc 4P403578-1F – 2018.06...
  • Page 8: Connecting The Water Piping

    Install a manometer in the system. Propylene glycol, including the necessary inhibitors, classified as Category III according to EN1717. NOTICE Install air purge valves at all local high points. WARNING Ethylene glycol is toxic. Installation manual EBLQ+EDLQ05+07CAV3 Daikin Altherma low temperature monobloc 4P403578-1F – 2018.06...
  • Page 9: To Fill The Water Circuit

    3 If an automatic air purge valve was installed, make sure it is open. 4 Fill the circuit with water until the manometer (field supply) indicates a pressure of ±2.0 bar. EBLQ+EDLQ05+07CAV3 Installation manual Daikin Altherma low temperature monobloc 4P403578-1F – 2018.06...
  • Page 10: To Connect The Main Power Supply

    Be careful NOT to pinch the wiring when attaching the frontplate to the unit. The main user interface is required for operation, but has to be ordered separately (mandatory option). 1 2 3 Installation manual EBLQ+EDLQ05+07CAV3 Daikin Altherma low temperature monobloc 4P403578-1F – 2018.06...
  • Page 11: To Connect The Shut-Off Valve

    If you do NOT configure the system correctly, it might NOT work as expected. The configuration influences the following: ▪ The calculations of the software EBLQ+EDLQ05+07CAV3 Installation manual Daikin Altherma low temperature monobloc 4P403578-1F – 2018.06...
  • Page 12: To Access The Most Used Commands

    Result: The user permission level switches to End user. The user interface will return to the default home screen. To modify an overview setting Example: Modify [1‑01] from 15 to 20. Installation manual EBLQ+EDLQ05+07CAV3 Daikin Altherma low temperature monobloc 4P403578-1F – 2018.06...
  • Page 13: Quick Wizard: Standard

    Disinfection 4 (3PN,(1/2)) 5 (3PN,(1/1+2)) Code Description [A.2.2.E.4] [E-05] DHW operation: Can the system prepare domestic hot water? ▪ 0 (No): NOT installed ▪ 1 (Yes): Installed Outdoor unit EBLQ+EDLQ05+07CAV3 Installation manual Daikin Altherma low temperature monobloc 4P403578-1F – 2018.06...
  • Page 14: Quick Wizard: Capacities (Energy Metering)

    Optional external kWh meter 2: ▪ 0 (No): NOT installed ▪ 1: Installed (0.1 pulse/kWh) ▪ 2: Installed (1 pulse/kWh) ▪ 3: Installed (10 pulse/kWh) ▪ 4: Installed (100 pulse/kWh) ▪ 5: Installed (1000 pulse/kWh) Installation manual EBLQ+EDLQ05+07CAV3 Daikin Altherma low temperature monobloc 4P403578-1F – 2018.06...
  • Page 15 [9-09] Heating: required temperature difference between entering and leaving water. In case a minimum temperature difference is required for the good operation of the heat emitters in heating mode. EBLQ+EDLQ05+07CAV3 Installation manual Daikin Altherma low temperature monobloc 4P403578-1F – 2018.06...
  • Page 16: Domestic Hot Water Control

    ▪ 1 (Reheat + sched.): Same as 2, but between the scheduled heatup cycles, reheat operation is allowed. ▪ 2 (Scheduled only): The domestic hot water tank can ONLY be heated according to a schedule. Installation manual EBLQ+EDLQ05+07CAV3 Daikin Altherma low temperature monobloc 4P403578-1F – 2018.06...
  • Page 17: Menu Structure: Overview Installer Settings

    Amp. limits for DI UFH screed dryout kW limits for DI Air purge Priority Actuator test run INFORMATION Depending on the selected installer settings and unit type, settings will be visible/invisible. EBLQ+EDLQ05+07CAV3 Installation manual Daikin Altherma low temperature monobloc 4P403578-1F – 2018.06...
  • Page 18: Commissioning

    The correct pipe size is installed and the pipes are properly insulated. There are no water leaks inside the outdoor unit. The shut-off valves are properly installed and fully open. Installation manual EBLQ+EDLQ05+07CAV3 Daikin Altherma low temperature monobloc 4P403578-1F – 2018.06...
  • Page 19: To Perform A Test Run

    ▪ [4‑01]≠1 3 Go to [A.7.4]: > Installer settings > Commissioning > Actuator test run. 4 Select an actuator and press . Example: Pump. 5 Select OK and press EBLQ+EDLQ05+07CAV3 Installation manual Daikin Altherma low temperature monobloc 4P403578-1F – 2018.06...
  • Page 20: Hand-Over To The User

    4 Select Lock or Unlock, and press To activate or deactivate button lock 1 Press to go to one of the home pages. 2 Press for more than 5 seconds. Installation manual EBLQ+EDLQ05+07CAV3 Daikin Altherma low temperature monobloc 4P403578-1F – 2018.06...
  • Page 21: Technical Data

    8 Technical data Technical data A subset of the latest technical data is available on the regional Daikin website (publicly accessible). The full set of latest technical data is available on the Daikin extranet (authentication required). Piping diagram: Outdoor unit...
  • Page 22: Wiring Diagram: Outdoor Unit

    Main PCB Reversing solenoid valve coil Current loop PCB Z1C~Z4C Ferrite core Plate heat exchanger heater tape Field wiring Expansion vessel heater Terminal strip Q*DI # Earth leakage circuit breaker Installation manual EBLQ+EDLQ05+07CAV3 Daikin Altherma low temperature monobloc 4P403578-1F – 2018.06...
  • Page 23 Overcurrent fuse booster heater English Translation Contactor booster heater (1) Connection diagram (1) Connection diagram # Domestic hot water pump Alarm output Alarm output # Shut-off valve Control box Control box EBLQ+EDLQ05+07CAV3 Installation manual Daikin Altherma low temperature monobloc 4P403578-1F – 2018.06...
  • Page 24 Switch box Extension PCB (control, optional) Q*DI # Earth leakage circuit breaker External indoor ambient sensor (4) Option switch box layout (4) Option switch box layout option Optional Field supply Installation manual EBLQ+EDLQ05+07CAV3 Daikin Altherma low temperature monobloc 4P403578-1F – 2018.06...
  • Page 25 3 core Control box power supply: 230 V + earth X1M: L-N-PE X1M: L-N-PE 2 core 230 V External indoor thermistor X2M: 1a-2a Power supply signal Only for KRCS01-1 4D09752-1C EBLQ+EDLQ05+07CAV3 Installation manual Daikin Altherma low temperature monobloc 4P403578-1F – 2018.06...
  • Page 28 4P403578-1F 2018.06...