Hide thumbs Also See for GM3500Xi:

Advertisement

Quick Links

R
GENMAX GENERATOR
INVERTER GENERATOR
USER'S MANUAL
GM3500Xi
Portable Inverter Generator
3200 Running Watts | 3500 Peak Watts
WARNING: SAVE THIS MANUAL FOR FUTURE REFERENCE
This manual contains important information regarding safety. Operation,
maintenance and storage of this product. Before use, read carefully and
understand all cautions, warnings, instructions and product labels. Failure to
do so could result in serious personal injury and/or property damage.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GM3500Xi and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for GENMAX GM3500Xi

  • Page 1 GENMAX GENERATOR INVERTER GENERATOR USER'S MANUAL GM3500Xi Portable Inverter Generator 3200 Running Watts | 3500 Peak Watts WARNING: SAVE THIS MANUAL FOR FUTURE REFERENCE This manual contains important information regarding safety. Operation, maintenance and storage of this product. Before use, read carefully and understand all cautions, warnings, instructions and product labels.
  • Page 2 DISCLAIMERS: All information, illustrations and specifications in this manual are based on the latest information available at the time of publishing. The illustrations used in this manual are intended as representative reference views only. Moreover, because of our continuous product improvement policy, we may modify information, illustrations and/or specifications to explain and/or exemplify a product, service or maintenance improvement.
  • Page 3: Limited Warranty

    3. WHO RECEIVES THIS WARRANTY(PURCHASER):The original purchaser (other than for purposes of resale) of the Genmax's inverter.4. WHAT PRODUCTS ARE COVERED BY THIS WARRANTY: Any portable generator supplied or manufactured by Warrantor.5. WHAT IS COVERED UNDER THIS WARRANTY: Substantial defects on material and workmanship which occur within the durat ion of the warranty period.
  • Page 4: Table Of Contents

    TABLE OF CONTENTS LIMITED WARRANTY SAFETY WARNING SAFETY INSTRUCTIONS NAMES OF COMPONENTS CONTROL FUNCTIONS PREPARATIONS 1.Fuel............................9 2.Oil...............................9 3.Pre-operation inspection......................10 STARTING UP THE GENERATOR SHUTTING DOWN THE GENERATOR USING THE GENERATOR 1.Service environment of the generator..................13 2.Generator wiring........................13 3.Generator grounding.........................14 SERVICE AND MAINTENANCE 1.Spark plug inspection.......................16 2.Adjustment of the carburetor.....................17 3.Replacement of oil........................17...
  • Page 5: Safety Warning

    SAFETY WARNING Personal and property safeties of you and others are very vital. Please read the Safety Warning in the User's Manual and the decals of the generator set carefully.The Safety Warning can alert you to those potential hazards that could harm you and others. In front of each Safety Warning, there is one of four words "DANGER"...
  • Page 6: Safety Instructions

    SAFETY INSTRUCTIONS Before operating the generator, it will help you avoid accidents to read and understand the Manual and familiarize yourself with the safe operation procedures of the generator. Please do not use in humid Please do not use indoors environment Please do not connect it to Please do not smoke when refueling...
  • Page 7 SAFETY INSTRUCTIONS SAFETY LABELS AND DECALS...
  • Page 8: Names Of Components

    NAMES OF COMPONENTS Fuel tank cap Fuel tank Generator frame Inverter Start handle Control panel Carburetor Muffler oil gauge Air cleaner...
  • Page 9: Control Functions

    CONTROL FUNCTIONS CONTROL PANEL FEATURES GM3500Xi ① 120-Volt, 20-Amp Duplex Outlet (NEMA 5-20R): ⑪ Parallel Connectors: To increase AC power output, The outlet is capable of carrying a maximum of 20 the connector sockets are used to connect the two same amps.
  • Page 10: Preparations

    PREPARATIONS Fuel DANGER • Fuel is flammable and toxic, please read the Safety Instruction carefully before refueling; • Do not fuel too full, otherwise fuel will spill after fuel tank is warmed; • After refueling, confirm that the fuel tank cap has been tightened. ATTENTION •...
  • Page 11: Pre-Operation Inspection

    PREPARATIONS Pre-use Inspection WARNING Even if the generator is not in service, its important component may suddenly fails. Before the generator is started up, if any of following components is unable to work properly, please inspect and repair carefully. Tip: The condition of the generator shall be inspected before using every time. Pre-operation inspection Fuel •...
  • Page 12: Starting Up The Generator

    STARTING UP THE GENERATOR Remove the load from all output ends; Turn fuel switch to "ON" position; Press LOW IDLE to "OFF"; Press main switch to "ON"; Pull the choke out; Tip: There is no need to pull out the damper when the engine is started in warm state.
  • Page 13: Shutting Down The Generator

    Plug in after started. SHUTTING DOWN THE GENERATOR Unplug the power cord; Press main switch to "OFF" position; Turn fuel switch to "OFF" position.
  • Page 14: Using The Generator

    USING THE GENERATOR Service environment of the generator • Applicable temperature: -5°C~ 40°C; • Applicable humidity: below 95%; • Applicable altitude: regions below 1,500 m (It shall be used by reducing power in regions above 1,000 m). Standard atmospheric condition •...
  • Page 15: Generator Grounding

    USING THE GENERATOR Connection of AC power WARNING All electrical equipment shall be disconnected before inserting the plug. ATTENTION • Make sure that all electrical equipment, including wires and plugs, are in good condition before connecting to the generator; • Make sure that all loads driven by the generator are within rated load range; •...
  • Page 16: Service And Maintenance

    SERVICE AND MAINTENANCE Good maintenance and service is the best guarantee for safe, economical and zero-failure operation. It also contributes to environmental protection. In order to keep the generator in good condition, you must inspect and maintain it regularly. The maintenance schedule is as follows: Then every three Maintenance cycle...
  • Page 17: Spark Plug Inspection

    SERVICE AND MAINTENANCE WARNING Please shut down the engine first before performing any maintenance. The engine shall be placed in a horizontal position. In order to prevent the engine from starting up, separate spark plug cap shall be separated from spark plug. Do not use it indoors or use it in a tunnel, cave or other places ventilated poorly.
  • Page 18: Adjustment Of The Carburetor

    SERVICE AND MAINTENANCE Install the spark plugs in reverse order of removal. Spark cold torque: 12.5 N.m Tip: If there is no torque wrench when installing the spark plug, a better estimation method is to screw it 1/4-1/2 turns by force after screwing it in place, but the spark plug shall be screwed to specified torque as soon as possible.
  • Page 19: Air Filter

    SERVICE AND MAINTENANCE Refill oil to a proper level, tighten oil dipstick, cover external cover plate and tighten the knob. Recommended oil: SAE S10W/30 Oil grade: API standard Model SJ or higher Volume: 0.12gal Air filter Dirty air cleaner may prevent air from flowing into the carburetor. In order to prevent failure of the carburetor, please maintain air cleaner regularly.
  • Page 20: Fuel Filter Screen

    SERVICE AND MAINTENANCE Fuel filter screen WARNING Be sure not to open fuel tank of the generator in a place where smoking or with flame. 1. Remove fuel tank cap and fuel tank filter screen. 2. Clean fuel tank filter screen with gasoline. 3.
  • Page 21: Storage And Transport

    STORAGE AND TRANSPORT Generator storage If it is stored long-term, in order to prevent aging, you shall take some storage measures. Follow the shutdown steps to shut down the generator. Open fuel tank cap, to take out fuel filter screen. Pump all fuel in fuel tank into special fuel tank, and then reassemble fuel tank cap back.
  • Page 22: Generator Transport

    STORAGE AND TRANSPORT Gently pull startup handle until you feel resistance, allowing both inlet valve and exhaust valve to be closed. Place the generator set in a clean and dry area. Generator transport • When the generator set is transported, it shall be ensured that there is no fuel spilling; •...
  • Page 23: Troubleshooting

    TROUBLESHOOTING...
  • Page 24 TROUBLESHOOTING...
  • Page 25: Technical Parameters

    TECHNICAL PARAMETERS Item GM3500Xi Rated Power (kW) Max. Power (kW) 164F/P Engine Model 64x45 Stroke x Bore (mm) Engine Type 4-stroke Displacement (cc) Gas Distribution Mode Cooling Mode Forced cooling wind Rated Speed (RPM) 4600 Starting Method Recoil start Fuel Tank Volume (gal)
  • Page 26: Circuit Diagram

    CIRCUIT DIAGRAM GM3500Xi SCHEMATICS...
  • Page 27: Choosinga Generator

    CHOOSING A GENERATOR...
  • Page 28 In production management, based on orderly, efficient, scientific principles. trying to do as better as possible in product design, development, production, inspection,etc. to make our production can keep orderly . And will continue to make improvement to make sure that keep the competitiveness.

Table of Contents