T O R Q U E S E T T I N G S F O R S C R E W S
TORQUE DRIVERS (Recommended): UTICA TS-30 (Shown)
TORQUE DRIVER (Alternate):
• Proto J6107A
• Wiha 28887
CAUTION! DO NOT OVER TORQUE SCREWS AS THIS CAN CAUSE LEAKAGE
ISSUES! TO CONFIRM THE IP65 INTEGRITY AFTER A LAMP REPLACEMENT, TEST
THE FIXTURE USING THE IP TESTER. CONTACT ADJ SERVICE FOR MORE DETAILS.
CAUTION! THE USE OF PROTECTIVE GLOVES AND SAFETY GOGGLES IS STRONGLY
RECOMMENDED WHILE PERFORMING THE IP PRESSURE TEST! AVOID PLACING
YOUR FACE, EYES, HANDS, ETC IN CLOSE PROXIMITY TO THE FIXTURE'S LENS
WHILE PERFORMING THE TEST!
Maximum Pressure
3.3 psi (23 KPa)
IP PRESSURE TESTING PARAMETERS
Minimum Pressure
2.9 psi (20 KPa)
34
Steady/Hold Time
15 sec