D M X S E T U P
DMX ADDRESSING.
All fixtures should be given a DMX starting address when using a DMX controller, so the correct fix-
ture responds to the correct control signal. This digital starting address is the channel number from
which the fixture starts to "listen" to the digital control signal sent out from the DMX controller. The
assignment of this starting DMX address is achieved by setting the correct DMX address on the digi-
tal control display on the fixture.
You can set the same starting address for all fixtures or a group of fixtures, or set different addresses
for each individual fixture. Setting all fixtures to the same DMX address will cause all fixtures to react
in the same way. In other words, changing the settings of one channel will affect all the fixtures simul-
taneously.
If you set each fixture to a different DMX address, each unit will start to "listen" to the channel number
you have set, based on the quantity of DMX channels of each fixture. That means changing the set-
tings of one channel will only affect the selected fixture.
For example, when this unit is operating in 17 channel mode, you should set the starting DMX
address of the first unit to 1, the second unit to 18 (1 + 17), the third unit to 35 (1 + 17 + 17), and so
on. See the chart below for more details.
CHANNEL MODE UNIT 1 ADDRESS UNIT 2 ADDRESS UNIT 3 ADDRESS UNIT 4 ADDRESS
17 Ch
20 Ch
22 Ch
1
18
1
21
1
23
23
35
52
41
61
45
67