GOBOS
REPLACEMENT PROCEDURE
1. Place the device on a flat, stable surface, and allow the device to cool down for at least 1 hour
before beginning this procedure.
2. Engage both the pan and tilt locks, and remove the head covers.
3. Locate the gobo module, which can be identified by finding the cooling fan located near the middle
of the module, as shown in the illustration below. Disconnect any electrical connectors linking the
module to the fixture head, and remove the screws holding the module in place. Slide the module
out of the head.
4. Pull the gobo holder away from the gobo wheel, then gently slide it outwards. Use a pair of needle
nose pliers to carefully remove the retainer spring from the gobo holder. The gobo can now be
removed from the gobo holder, and replaced with a new gobo. Reassemble by reversing these steps.
17