Regulations; Dimensions; Heat Pump Dimensions - Bosch AW 4 OR-S Installation Instructions Manual

Air to water heat pump
Table of Contents

Advertisement

4
3
2
Fig. 3
Product Overview back view
[1]
Condenser
[2]
Pressure sensor high pressure
[3]
Pressure switch sensor high pressure
[4]
Dry filter (mounted at service action)
[5]
Manual de-airing valve
[6]
Evaporator
Open the de-airing valve when filling the system and close it when no
more air is coming out.
2.6

Regulations

Follow the directives and regulations given below:
• Local provisions and regulations of the electricity supplier and
corresponding special rules
• National building regulations
• EN 50160 (voltage properties in power grids for public distribution)
• EN 12828 (heating systems in buildings - Design and installation of
water-based heating systems)
• EN 1717 (Protection of potable water against pollution in potable
water installations)
• EN 378 (Refrigerating systems and heat pumps - Safety and
environmental requirements)
• EN60335-2-40 (Particular requirements for electrical heat pumps,
air-conditioners and dehumidifiers)
• PED, 2014/68/EU (Pressure equipment directive)
AW 4 | 5 | 7 OR-S – 6721866761 (2023/06)
5
6
1
0010039863-004
2.7

Dimensions

2.7.1

Heat pump dimensions

87 90
1
Fig. 4
Heat pump dimensions and connections, rear
[1]
Type plate
The type plate contains information on the output, part number and
serial number and also the date of manufacture.
Fig. 5
Heat pump dimensions, top
330
Fig. 6
Distances to drain connector, bottom view
[F]
front
Product description
1100
0010042487-002
107
0010039106-003
881
F
0010044592-003
5

Advertisement

Table of Contents