12 V AC (code B4) / 24 V AC (code C4)
Position of the connectors
Electrical connection
5
4
6
3
1
2
Plug assignment UV
Pin
L1, supply voltage
1
N, supply voltage
2
L1, change-over (OPEN/CLOSED)
3
N, change-over (OPEN/CLOSED)
4
n.c.
5
n.c.
6
PE, protective earth conductor
Preferred direction -OPEN- when all signals are present
Connection diagram
5
4
6
1
S2
External
wiring
S1
Connection diagram X1, UV
S1
0
OFF
1
ON
S2
0
CLOSED
1
OPEN
www.gemu-group.com
Actuator version 1006
S1/S2 UV
Description
3
2
0 1
0 1
L1 N
Uv
Actuator
Direction of travel
Actuator version 2015
UV
S1/S2
5
4
6
3
1
2
Plug assignment S1/S2
Pin
1
Change-over contact limit switch CLOSED
2
Make contact limit switch CLOSED
3
Break contact limit switch CLOSED
4
Break contact limit switch OPEN
5
Make contact limit switch OPEN
6
Change-over contact limit switch OPEN
PE, protective earth conductor
OPEN
Additional
limit switches
1
4
2
6
1