Aids for calculating the field data
You will also find a tool for calculating field data on the DVD "Ident Systems, Software &
Documentation". Using this tool, among other things you can calculate the operating
distance (S
Figure 4-10
4.2

Field data for transponders, readers and antennas

The following tables show the field data for all SIMATIC RF300 components of transponders
and readers. This makes the correct selection of a transponder and reader particularly easy.
All the technical specifications listed are typical data and are applicable for an ambient
temperature between 0 °C and +50 °C, a supply voltage between 22 and 27 VDC and a
metal-free environment. Tolerances of ±20 % are permitted due to production or temperature
conditions.
If the entire voltage range at the reader of 20 VDC to 30 VDC and/or the entire temperature
range of transponders and readers is used, the field data is subject to further tolerances.
Note
Transmission gaps
If the minimum operating distance (S
center of the field. Communication with the transponder is not possible in the transmission
gap, see section "Impact of secondary fields (Page 43)".
SIMATIC RF300
System Manual, 07/2017, C79000-G8976-C345-07
), limit distance (S
) and transmission window (L).
a
g
User interface of the calculation tool for field data acquisition
4.2 Field data for transponders, readers and antennas
) is not observed, a transmission gap can occur in the
a
Planning the RF300 system
51