steam Installation, Operating & Maintenance Instructions ________________________________________________________________________________________________ A i r Te m p o ® Wireless Touch Control with Steamhead Installation, Operation & Maintenance Manual ®...
steam steam Installation, Operating & Maintenance Instructions Installation, Operating & Maintenance Instructions ________________________________________________________________________________________________ ________________________________________________________________________________________________ table of Contents: reaD me FirSt! When installing and using this electrical equipment, basic safety precautions should always be followed, including the following: IMPORTANT SAFETY INSTRUCTIONS Important Safety Instructions ........2 As you follow these instructions, you will notice warning and WarNiNG...
Doing so may result in an inoperative or hazardous installation. or similar within the shower could cause confusion or interfere with the MrSteam • Cable (3 ft.) Do not alter or modify any Mr. Steam product. Doing so may result in 3/4” control’s intended use and function.
Page 4
________________________________________________________________________________________________ ________________________________________________________________________________________________ installation instructions for airtempo Step 2 Flush mount airtempo The AirTempo control can be surface or flush Step 1 impOrtaNt NOte: Flush mount components are sold separately impOrtaNt NOte: Do not apply mounted according to personal preference. Determine the desired installation location of the control. The AirTempo (104232RD &...
(PN: MSTS) DiaGram 1 The Remote Temperature Probe is required when the AirTempo control is 2. Drill a 5/16 inch diameter hole in the wall. Do not oversize or Temperature installed outside the steam room.
steam steam Installation Instructions Operating Instructions ________________________________________________________________________________________________ ________________________________________________________________________________________________ 5. Route the end of the probe cable with the temperature probe airtempo Operating instructions WarNiNG Insure a minimum of 1/4” of the temperature probe is exposed Diagram 1 through the wall into the steam room as shown in Diagram 2. to the air.
Page 7
Press it twice to program PROG2. The selected setting will be displayed. turn light on. Press twice to select the next color. Press again AirTempo control. After 10 minutes the steam generator turns off if the User Preset Enter the preferred time and temperature settings.
2. Do not use abrasive cleansers WarNiNG CHOKE HAZARD. The batteries and battery doors are small err C indicates the AirTempo control has lost communication with the steam pieces, keep out of reach of children. 3. If the decorative cover is damaged call MrSteam generator.
steam steam Maintenance Instructions Maintenance Instructions ________________________________________________________________________________________________ ________________________________________________________________________________________________ FCC/industry Canada two part Statement: parts List: template This device complies with FCC Part 15 and Industry Canada license exempt NOte: This equipment has been tested and found to comply with the limits ITEM # DESCRIPTION USED ON...
Page 11
www.mrsteam.com Products, information and specifications are subject to change without notice. For more information call Sales & Support at: 1.800.76.STEAM 1.800.72.STEAM (East Coast) (West Coast) mr.steam Sussman-Automatic Corporation hello@mrsteam.com www.mrsteam.com ® 43-20 34th Street, Long island City NY 11101 9410 S. La Cienega Blvd., Inglewood CA 90301 800 767 8326 : 718 472 3256 800 72 8326...