Page 1
steam ® Installation, Operating & Maintenance Instructions ________________________________________________________________________________________________ A i r Te m p o ® Wireless Touch Control with Steamhead Installation, Operation & Maintenance Manual ®...
steam ® Installation, Operating & Maintenance Instructions ________________________________________________________________________________________________ When installing and using this electrical equipment, basic safety precautions should always be followed, including the following: IMPORTANT SAFETY INSTRUCTIONS 1. READ AND FOLLOW ALL INSTRUCTIONS thermia). Limit your use of steam to 10-15 HypertHermia occurs when the internal minutes until you are certain of your body’s...
Indicates a potentially hazardous situation, which could WarNiNG Remote Temperature Probe ......9-11 result in death or serious injury. AirTempo Operating Instructions ....12-14 Indicates a potentially hazardous situation, which may result CaUtiON Battery Replacement ..........15 in minor or moderate injury or product damage.
Failure to turn the power off will result in an inoperable control. inoperative or hazardous installation. • Do not operate AirTempo, iTempoPlus, iTempo, Home Wizard or iGenie controls with A peel and stick warning sticker is provided in the MrSteam steam WarNiNG anything other than a MrSteam eTempo compatible steam generator.
Construction materials affect the communication between the control and the bayonet to the wall as required for rough or uneven wall receiver. Test the range of the AirTempo. It may be necessary to change surfaces. The surface mount bayonet supports the weight of the the location of the wireless receiver to improve the range.
Installation Instructions ________________________________________________________________________________________________ mounting on Glass When installing AirTempo on glass a peel and stick film is provided on pages 20-21 and may be used as a mask for a clean look from behind the glass. Wireless receiver installation Steam...
Page 8
RF signal. The control features an integral temperature sensor. AirTempo Control Locate the control in a location representative of the Surface or Flush Mount desired steam bathing temperatures. Do not locate...
CaUtiON emissions may result in poor steam room temperature control. AirTempo control is installed outside the steam room. Failure to install the probe, or failure to install the probe correctly will result in an inoperable d. The probe has an integral 30’ cable. Insure that the probe and/or control and result in excessive temperatures and a hazardous condition.
Page 10
steam ® Installation Instructions ________________________________________________________________________________________________ DiaGram 1 Temperature Probe Connection Knock-Out Temperature Probe Cable Temperature (30 feet) Sensor Probe Mr.Steam Steam Generator (shown with cover removed and NOT installed) Drawings for Illustrative Purposes Only.
Page 11
steam ® Installation Instructions ________________________________________________________________________________________________ Insure a minimum of 1/4” of the temperature probe is exposed 5. Route the end of the probe cable with the temperature probe WarNiNG to the air. Failure to do so may interfere with the ability to sense tempera- through the wall into the steam room as shown in Diagram 2.
Installation Instructions ________________________________________________________________________________________________ airtempo Operating instructions Diagram 1 ON/OFF Diagram 1 The AirTempo features programmable temperature control, programmable time duration, AromaSteam Press the ON/OFF key for 1 second to start the ON/OFF, ChromaSteam control and two personal flow of steam. The Temperature Set Point is ®...
Page 13
Press it twice to program PROG2. The selected setting will be displayed. Enter the preferred time and temperature settings. User Preset The AirTempo will store the following settings: Set point, Time duration & Aroma state. To select PROG1 or PROG2: Press ON/OFF key then press key once to select PROG1, press it twice to select PROG2.
Page 14
After 10 min- only be lit when the display is ON. utes the steam generator turns off if the AirTempo is not returned to its dock. The steam generator will not restart unless AirTempo is in its dock.
Immedi- ately see a doctor. Remove the AirTempo from the wall by sliding it up and off the bayonet holder. The AirTempo comes off the flush mount holder by grasping the bezel and pull- ing the assembly straight out of the flush mount box.
AirTempo controls must be paired to their transceivers to prevent interference. To pair AirTempo use a blunt object to press the button inside the transceiver adjacent to the LED. Hold the button for 5 seconds, when the transceiver is in pairing mode the LED will turn blink blue for 2 minutes.
Instead, it is the user’s responsibility to dispose of their waste equipment by airtempo Control and Wireless receiver handing it over to a designated collection point for the recycling of The objects of the declaration described here are in conformity with the waste electrical and electronic equipment.
steam ® Maintenance Instructions ________________________________________________________________________________________________ (For North American Version) FCC/industry Canada two part Statement: NOte: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits This device complies with FCC Part 15 and Industry Canada license exempt RSS standard(s).
910 ~ 920 MHz (North American Version) 104211 Surface Mount Holder Surface Mount Operating voltage 5.0 V ( provided by Steam Generator Unit ) (AirTempo Surface) airtempo Control Unit 104212 Wireless Receiver Temperature operating -20 C ~ +60 C 104213XX Round Beze Flush mount Temperature storage -30 C ~ +60 C (limited by battery &...
NOte: Flush mount components are sold separately (104232RD & 104232SQ). Contact a MrSteam representative if a flush mount kit is needed. • Remove the surface mount bayonet from the back of the AirTempo control. The surface mount bayonet is not used when flush mounting. The surface mount decorative bezel is not used when flush mounting.
steam ® ________________________________________________________________________________________________ Place the electronic assembly into the decorative template bezel as shown. The retention ring snaps onto the For Flush Mount Kit Installation assembly from behind. The 3 piece assembly can then be placed into the flush mount box. There is a magnet in the box that will hold the control in place.
Page 24
www.mrsteam.com Products, information and specifications are subject to change without notice. For more information call Sales & Support at: 1.800.76.STEAM 1.800.72.STEAM (East Coast) (West Coast) mr.steam Sussman-Automatic Corporation hello@mrsteam.com www.mrsteam.com ® 43-20 34th Street, Long island City NY 11101 9410 S. La Cienega Blvd., Inglewood CA 90301 800 767 8326 : 718 472 3256 800 727 8326...
Need help?
Do you have a question about the AirTempo and is the answer not in the manual?