Intex 128366NP Owner's Manual page 65

Frame pool set ultra quadra 732 x 366 x 132 cm
Table of Contents

Advertisement

(261IO) Sand Filter Pump & Saltwater System with Electrocatalysis Oxidation (14" & 16") ENGLISH 7.5" X 10.3" PANTONE 295U 06/20/2016
TROUBLESHOOTING GUIDE (continued)
PROBLEM
INSUFFICIENT
• Without cyanuric acid.
CHLORINE
• Insufficient operating hours of the
Saltwater System.
• The salt level in the pool water
is less than 2000 ppm. This is
insufficient.
• Chlorine loss due to intense
sunlight exposure.
• The bather load has increased.
• Clogged or dirty electrolytic cell.
• High UV level exposure.
• Excessive calcium hardness is
WHITE FLAKES IN
THE WATER
present in pool water.
NO LED DISPLAY
• No power supply.
• RCD has not reseted.
• A power fuse has blown.
• LED failure.
SAVE THESE INSTRUCTIONS
CAUSE
• See "Cyanuric acid table".
• Increase the daily Saltwater System operating
time. See "Operating Instructions".
• Check the salt level with the Test Kit. Adjust as
needed. See "Salt & Pool Water Volumes".
• Use a pool cover when the pool is not in use
and/or when the unit is operating.
• Increase the daily Saltwater System operating
time. See "Operating Instructions".
• Remove the cell for inspection, clean it if
necessary. See "Maintenance".
• Cover the pool with a pool cover for 2 days
with the device running and then test the water
using the test strips.
• If the pool is clean and clear, add stabilizer to
the water and then test the water with the
device running.
• Drain about 20 to 25% of the pool water and
add fresh water to decrease the calcium
hardness. Inspect the electrolytic cell for scale
buildup. Clean the electrolytic cell if necessary.
• Plug the cell cord firmly into the cell housing
receptacle.
• Reset the RCD.
• Contact Intex Service Center.
• Contact Intex Service Center.
English
261A
SOLUTION