Operating conditions and
specifications
2.1

Operating conditions for the 707 control valve

Table 2-1: Operating conditions for the control valve
Condition type
Fluid phase
Process temperature
Fluid velocity
Fluid(s) controlled
Viscosity limits
Differential pressure
Sizes (NPS)
Pressure class (ANSI)
Maximum safe working
temperature range
Maximum safe working pressure
User manual

Operating conditions and specifications

Description
Liquid
-29 °C to 66 °C (-20 °F to 150 °F)
Operational recommended flow velocity up to 30 ft/sec,
beyond this point will result in a high pressure drop and
increased wear.
Low/Medium viscosity crude oils and condensates
Refined products and intermediates (ie: gasoline, diesel,
kerosene, light fuel oils, jet fuel, LPG, butanes, naphtha,
alkylate, reformate, straight run gasoline, cat-cracked
gasoline)
Petrochemicals (ie: benzene, toluene, xylenes, cumene,
olefins, pyrolysis gasoline)
Natural gas liquids
Maximum valve viscosity is 8800 Cst
The maximum allowable differential pressure across a control
valve is 6894 kPa (1,000 psi). Consult factory for location of
first shut down valve.
2, 3, 4
150, 300, 600
-26 °C to 204 °C (15 °F to 400 °F)
®
Using Viton
O-rings
Consult the factory for other safe working temperatures
Flange connections/Ratings (ANSI) for valve sizes 2"- 4":
Class 150 MWP at 100 °F: 285 psi
Class 300 MWP at 100 °F: 740 psi
Class 600 MWP at 100 °F: 1480 psi
* MWP: Maximum Working Pressure