First Fire; Fan Operation (All Units); Ash Disposal; Some Safety Guidelines - Regency Fireplace Products Classic H2100M Owners & Installation Manual

Wood fireplace insert & hearth heater
Table of Contents

Advertisement

How to Light & Maintain a Wood Stove Fire

FIRST FIRE

When your installation is completed and in-
spected, you are ready for your first fire.
1) Open draft control fully.
2) Open firebox door and build a small fire using
paper and dry kindling, wait a few minutes
for a good updraft in the flue to establish the
fire. Leaving the door slightly open will help
your fire start more rapidly.
CAUTION: Never leave unit unat-
tended if door is left open. This
procedure is for fire start-up only,
as unit may over-heat if door is left
open for too long.
3) With the draft still in the fully open position,
add two or three seasoned logs to your fire.
Form a trench in the ash bed to allow air to
reach the rear of the firebox prior to closing
the door.
4) After about 15 to 20 minutes, when your
wood has begun to burn strongly, adjust
your draft control down to keep the fire at a
moderate level.
WARNING: Never build a roaring
fire in a cold stove. Always warm
your stove up slowly!
5) Once a bed of coals has been established,
you may adjust the draft control to a low
setting to operate the unit in its most efficient
mode.
6) During the first couple of hours, keep the
combustion rate at a moderate level and
avoid a large fire until the paint is cured.
Only then can you operate the insert at its
maximum setting, and only after the metal
has been warmed.
7) For the first few hours, the insert will give
off an odour from the paint. This is to be
expected as the high temperature paint
becomes seasoned. Windows and/or doors
should be left open to provide adequate
ventilation while this temporary condition
exists. Burning the insert at a very high
temperature the first few times may damage
the paint. Burn fires at a moderate level the
first few days.
8) Do not place anything on the insert top
during the curing process. This may result
in damage to your paint finish.
9) During the first few hours it may be more dif-
ficult to start the fire. As you dry out your fire
brick and your masonry flue (if applicable),
your draft will increase.
10) For those units installed at higher elevations
or into sub-standard masonry fireplaces,
drafting problems may occur. Consult an
experienced dealer or mason on methods
of increasing your draft.
11) Some cracking and popping noises may be
experienced during the heating up process.
These noises will be minimal when your unit
reaches temperature.
12) Before opening your door to reload, open
draft fully for approximately 10 to 15 seconds
until fire has been re-established. This will
minimize any smoking.
13) All fuel burning appliances consume oxygen
during operation. It is important that you
supply a source of fresh air to your unit
while burning. A slightly opened window is
sufficient for this purpose.
CAUTION: If the body of your unit
(or in the H2100M flue baffle) starts
to glow you are overfiring. Stop
loading fuel immediately and close
the draft control until the glow has
completely subsided.
14) Green or wet wood is not recommended for
your unit. If you must add wet or green fuel,
open the draft control fully until all moisture
has been dispersed by the intense fire.
Once all moisture has been removed, the
draft control may be adjusted to maintain
the fire.
15) If you have been burning your insert on a low
draft, use caution when opening the door.
After opening the damper, open the door
a crack, and allow the fire to adjust before
fully opening the door.
16) The controls of your unit should not be altered
to increase firing for any reason.
FAN OPERATION
(ALL UNITS)
The fan is to be operated only with the draft
control rod pulled out at least 1/2" from the
fully closed position. The fan is not to be
operated when the draft control rod is in the
closed position (pushed in). The fully closed
position is the low burn setting.
The fan unit must not be turned on until a fire
has been burning for at least 30 minutes and
the unit is hot enough. As well, after each fuel
loading the fan must be shut off until 30 minutes
has elapsed.
To operate fan automatically, push switch on side
of fan housing to "Auto" and second switch to
either "High" or "Low" for fan speed. The auto-
operating instructions
matic temperature sensor will engage the blower
when the unit is at temperature and will shut off
the blower once the fire has gone out and the unit
has cooled to below a useful heat output range.
To manually operate the fan system, push the
first switch to "Man" and second switch to either
"high" or "Low". This will bypass the sensing
device and allow full control of the fan. Switching
from "Auto" to "Manual" or "High" to "Low" may
be done at any time.

ASH DISPOSAL

During constant use, ashes should be removed
every few days. Please take care to prevent the
build-up of ash around the start-up air housing lo-
cated inside the firebox, under the loading door lip.
DO NOT ALLOW ASHES TO BUILD UP TO THE
LOADING DOORS.
Only remove ashes when the fire has died down.
Even then, expect to find a few hot embers. Always
leave 1 to 2 inches of ash in the bottom of the
firebox. This helps in easier starting and a more
uniform burn of your fire.
Ashes should be placed in a metal container with a
tight fitting lid. The closed container of ashes should
be placed on a noncombustible floor or on the
ground, well away from all combustible materials,
pending final disposal. If the ashes are disposed
of by burial in soil or otherwise locally dispersed,
they should be retained in the closed container
until all cinders have thoroughly cooled. Other
waste should not be placed in the ash container.
SOME SAFETY
GUIDELINES
1) Never use gasoline, gasoline type lantern
fuels, kerosene, charcoal lighter fuel, or similar
liquids to start or 'freshen up' a fire in your
heater. Keep all such liquids well away from
the heater while it is in use.
2) Keep the door closed during operation and
maintain all seals in good condition.
3) Do not burn large quantities of paper in your
insert.
4) If you have smoke detectors, prevent smoke
spillage as this may set off a false alarm.
5) Do not overfire your insert. Attempts to
achieve heat output rates that exceed heater
design specifications can result in permanent
damage to the heater If the insert or its flue
baffle begin to glow, you are overfiring. Stop
adding fuel and close the draft control. Over-
firing can cause extensive damage to your
stove including warpage and premature steel
corrosion. Overfiring will void your warranty.
6) Do not permit creosote or soot buildup in the
chimney system. Check and clean chimney
at regular intervals.
Regency Wood Insert & Hearth Heater
|
17
|
17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Classic i3100l

Table of Contents