DAV TECH PCP Operating Instructions Manual page 20

Olumetric pump drive
Table of Contents

Advertisement

Operating instructions
There are also 4 outputs that define the drive's status:
Alarm
When 1 or more hardware alarms are active in the drive
Ready
When there are no alarms and the motor is in torque (enable active)
End of dispensing
Signal that activates at the end of a predetermined dispensing
Dispensing in progress
Signal that allows you to connect for example a solenoid at the output of the pump (with a
programmable delay)
INPUT
PIN
INGRESSO
PIN
OUT 0
13
OUT 0
13
OUT 1
30
OUT 1
30
OUT 2
22
OUT 2
OUT 3
22
23
OUT 3
23
5.4 Interfacing via Profinet
Interfacciamento via Profinet
The drive in the upper part has 2 ethernet ports which are related to a single network interface.
Il drive nella parte superiore presente 2 porte ethernet che sono relative ad un'unica
It is possible to insert one or more drives into the PLC network configuration using the supplied
interfaccia di rete. È possibile inserire uno o più drive nella configurazione di rete del
GSDML file. The real time data exchange must be configured in the Drive using the "PROFIdrive
AEC Telegram 500 " (programmable delay).
PLC utilizzando il file GSDML fornito. Lo scambio dati real time dovrà essere configurato
nel Drive utilizzando il "PROFIdrive AEC Telegram 500".
Questo telegramma predispone lo scambio di 10 variabili INT32 per gli ingressi e 10
This telegram sets up the exchange of 10 INT32 variables for the inputs and 10 INT32 variables for
variabili INT32 per le uscite (40 + 40 Byte).
the outputs (40 + 40 Byte).
AZIONAMENTO POMPE VOLUMETRICHE PCP
DESCRIPTION
DESCRIZIONE
Alarm
Allarme
Ready
Ready
End of dispensing
Fine dosaggio
Dispensing in progress
Dosaggio in corso