4 INSTALLATION

FEATURE
Operating temperature
Cooling
Operating humidity
Storage temperature
Storage humidity
Place of installation
Altitude
Vibration resistance
Shock resistance
Operating conditions
Place of installation
0°C ... +50°C
Ventilate the drive in case of continuous operation
95% relative or lower humidity (without condensation)
-20°C ... +70°C
95% relative or lower humidity (without condensation)
Free of corrosive gases
Free of dust and iron powder
Not subject to moisture or lubricating oil such as cutting oil
1,000 m or less
4,9 m/s2
19,6 m/s2
Installation category (overvoltage category): III
Pollution degree: 2 or better
Protection class: IP3X (EN50178)
Installing in a control panel
Installation near a heating
module
Installation near a vibration
source
Installation in a place
exposed to corrosive gases
SPECIFIC
Design the control panel size, module layout and cooling
method so that the temperature around the drive does not
exceed 50 ° C. Note: To increase product life and maintain
reliability, keep the temperature inside the control panel
below 40 ° C.
Minimize thermal radiation from the heating module and any
temperature rises caused by natural conversion, so that the
temperature around the drive does not exceed 55 ° C.
Install a vibration damper below the drive to avoid subjecting
it to excessive vibration.
Corrosive gases do not have an immediate effect on the
device but, in the long term, cause malfunctions of the
electronic components. Take appropriate measures to avoid
the presence of corrosive gases.