PCP VOLUMETRIC PUMP DRIVE
DAV TECH SRL
Via Ravizza, 30 - 36075 Montecchio Maggiore (VI) - ITALIA
Tel. 0039 0444 574510 - Fax 0039 0444 574324
davtech@davtech.it - www.davtech.it

Advertisement

Table of Contents
loading

Summary of Contents for DAV TECH PCP

  • Page 1 Operating instructions PCP VOLUMETRIC PUMP DRIVE DAV TECH SRL Via Ravizza, 30 - 36075 Montecchio Maggiore (VI) - ITALIA Tel. 0039 0444 574510 - Fax 0039 0444 574324 davtech@davtech.it - www.davtech.it...
  • Page 2 Operating instructions Index 1 INTRODUCTION pag. 3 1.1 The manual 1.2 Warranty 1.3 Goods receipt 2 TECHNICAL DESCRIPTION pag. 3 2.1 Operation 2.1 Technical specifications 3 SAFETY STANDARDS pag. 4 3.1 Safety notes 4 INSTALLATION pag. 10 4.1 Panel installation 4.2 Thermal dissipation 4.3 Electrical connections 4.4 Power supply...
  • Page 3: Technical Description

    DAV Tech is prohibited. The texts and illustrations contained in the manual are not intended to be binding, DAV tech reserves the right, at any time and without notice, to make any changes to improve the product or for constructive or commercial needs.
  • Page 4: Safety Standards

    Operating instructions 3 SAFETY STANDARDS It is recommended to follow the instructions below in order to avoid damage to the system, the device, or injury to the technician, or to other people during operation. Throughout this manual, the following symbols are used to indicate the possible danger levels if the installation instructions are not followed.
  • Page 5 PCP VOLUMETRIC PUMP DRIVE DANGER Read the following instructions in their entirety before checking the products at the time of delivery, before transport and storage, installation, wiring, operation, inspection, and disposal. Make sure you have correctly connected the connectors and fixed the cables.
  • Page 6 Operating instructions REQUIRED During installation, protections must be provided for over-currents, for electricity leakage, for over-temperatures, as well as emergency stop devices. Failure, in the absence of protection, can cause electrical shock, injury or fire. Strictly follow the instructions and procedures contained in this manual to verify the correct installation.
  • Page 7 Failure to observe this warning can cause deterioration of the internal components with consequent fires or malfunctions. DAV Tech products are precision equipment. Avoid violent shocks during transportation, installation, and operation. Failure to observe this warning can cause malfunctions.
  • Page 8 Operating instructions Securely connect the power terminals. Use cables with a section suitable for their use. Failure to observe this warning can cause a fire. Keep the power and signal lines at a distance of at least 300mm. Use twisted pairs or shielded cables.
  • Page 9 • This manual is subject to change due to product improvements, specification changes or improvements to the manual. • DAV Tech srl is not responsible for damage to things and / or people caused by incorrect installations and / or unauthorized modifications of the product.
  • Page 10: Installation

    Operating instructions 4 INSTALLATION SPECIFIC FEATURE 0°C ... +50°C Operating temperature Ventilate the drive in case of continuous operation Cooling 95% relative or lower humidity (without condensation) Operating humidity -20°C ... +70°C Storage temperature 95% relative or lower humidity (without condensation) Storage humidity Free of corrosive gases Free of dust and iron powder...
  • Page 11 PCP VOLUMETRIC PUMP DRIVE Le dimensioni sono espresse in mm. SPECIFIC FEATURE 320 g Weight Complies with U.L. Spec 94 V-0 Flammability Rating Cover material . 11...
  • Page 12 Operating instructions 4.1 Panel installation If installed inside an electrical panel, leave a free space of at least 50 mm around the module in case of the installation of a single drive. If more drives are installed, respect the minimum space, as shown in the following figure, between two contiguous drives, in order to guarantee air flow and cooling of the modules.
  • Page 13 The trend of the thermal dissipation in relation to the supplied current is shown below. Watts Amperes The electric current required to control the PCP pumps is 2.5 A. 4.3 Electrical connections Below is the trend of the thermal dissipation in relation to the supplied current.
  • Page 14 The maximum absorption for a PCP pump is about 2.5 A while the drive logic is about 200-300mA.
  • Page 15 PCP VOLUMETRIC PUMP DRIVE To reduce EMI disturbances, it is required to install a ferrite filter at a maximum distance of 150 mm from the drive on the motor cable. The filter is composed of low-grade ferrite which has high radio frequency losses; in this way the filter works as a high impedance at those frequencies.
  • Page 16: Connection Diagram

    Operating instructions ATTENTION The digital outputs are protected against overloads (Max 500mA) and short-circuits; in case of overload the output will switch off until the anomaly is removed. If inductive loads, such as relays, solenoid valves, etc. have to be driven, connect a flyback diode in parallel to the load.
  • Page 17 PCP VOLUMETRIC PUMP DRIVE 2 3 4 5 6 7 8 9 Components identification 2 3 4 5 6 7 8 9 Power supply and motor Service input connector (M2) connector (M1) PIN Signal name Description PIN Signal name Description...
  • Page 18 Operating instructions Il programma all’interno del drive prevede già le seguenti connessioni sul connettore M2: CONNECTION NAME PROGRAMME FUNCTION 5 VDC encoder 5 V encoder power supply (max 100mA) GND encoder GND encoder Channel A + encoder Channel A + encoder Channel B + encoder Channel B encoder Channel Z + encoder (Top)
  • Page 19 5V present on terminal board M2. 5.3 Drive logic The drive has been designed to perform all the dispensing functions necessary for a PCP pump, these functions can all be parameterized via Modbus TCP IP , without this communication it will be possible to use the drive with only one static data set.
  • Page 20 End of dispensing Signal that activates at the end of a predetermined dispensing Dispensing in progress Signal that allows you to connect for example a solenoid at the output of the pump (with a AZIONAMENTO POMPE VOLUMETRICHE PCP programmable delay) INPUT DESCRIPTION...
  • Page 21 PCP VOLUMETRIC PUMP DRIVE Drive Modbus holding PLC input Description variables register Status Bit 0 alarm Bit 1 Ready Bit 2 End of dispensing Var_1 V111 4-1222 Bit 3 Dispensing Bit 4 Power Enablement Alarm Bit 5 Standby Bit 6 Pressure alarm...
  • Page 22 Operating instructions Drive Modbus holding PLC input Description variables register Commands Bit 0 Free Bit 1 Enable Var_1 V101 4-1202 Bit 2 Continuous dispensing Bit 3 Predetermined dispensing Bit 4 Alarms reset Bit 5 EV Output Command Dispensing speed Var_2 V102 4-1204 in rpm...
  • Page 23 The programming of the IP ADDRESS for the only Modbus TCP / IP communication can be done through the specific software supplied DCCONTROL. 6 CONNECTION BETWEEN DRIVE AND PUMP The cable supplied for the connection of the PCP pump is a 7 meter long shielded PUR cable suitable for handling. Below the connection table: DESCRIPTION...
  • Page 24: Electrical Diagram

    Sistemi di dosaggio Via Ravizza 30 Montecchio Maggiore (VI) Italy DAV TECH SRL Via Ravizza, 30 - 36075 Montecchio Maggiore (VI) - ITALY - Ph. 0039 0444 574510 - Fax 0039 0444 574324 davtech@davtech.it - www.davtech.it We reserve the right to modify at any time, without notice, the technical characteristics, dimensions and weights indicated in this manual. Illustrations are not challenging.