Yamaha YFM700PF Owner's Manual page 127

Table of Contents

Advertisement

1. Water pump air bleed bolt
15. When coolant begins to flow out of the bolt
hole, tighten the water pump air bleed bolt to
the specified torque.
Tightening torque:
Water pump air bleed bolt:
10 Nm (1.0 m·kgf, 7.2 ft·lbf)
16. Remove panel E. (See page 8-10.)
17. Loosen the clamp screw, and then remove
the V-belt cooling duct.
1
1. V-belt cooling duct
2. Clamp screw
18. Loosen the cylinder head air bleed bolt, with-
out removing it, to allow all of the air to es-
cape from the air bleed bolt hole.
8-36
8

Advertisement

Table of Contents
loading

This manual is also suitable for:

Grizzly 700Yfm700phfYfm700psfYfm700plfYfm700fwad

Table of Contents