Xylem Flygt 3060 Installation, Operation And Maintenance Manual page 38

Table of Contents

Advertisement

Technical Reference
1-phase, 60 Hz
Motor type:
• Rated output 1.9 kW (2.5 hp)
Voltage (V)
230
240
3-phase, 50 Hz
Motor type:
• Rated output 2.4 kW (3.2 hp)
Voltage (V)
190 Y
200 D
200 Y
200 Y parallel
208 D
220 D
230 D
346 Y
350 Y
380 D
380 Y
400 D
400 Y
400 Y
400 Y serial
415 Y
440 Y
500 Y
550 Y
660 Y
690 Y
3-phase, 60 Hz
Motor type:
• Rated output 2.7 kW (3.6 hp)
Voltage (V)
200 Y
208 Y
220 Y
220 Y parallel
230 D
230 Y parallel
36
Rated current (A)
10
9.6
Rated current (A)
10
9.9
10
9.8
9.4
9
8.5
5.7
5.6
5.2
5.2
4.9
4.9
5.1
4.9
4.8
4.5
3.9
3.5
3
2.9
Rated current (A)
11
10
9.8
9.9
9
9.4
Flygt 3060 Installation, Operation, and Maintenance Manual
Starting current (A)
56
48
59
49
50
43
45
28
28
24
25
26
26
21
25
22
23
21
18
14
15
Starting current (A)
56
58
62
51
48
50

Advertisement

Table of Contents
loading