Lenovo 7X12 Reference Manual page 31

Messages and codes reference
Table of Contents

Advertisement

Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Temperature
SNMP Trap ID: 0
CIM Prefix: PLAT CIM ID: 0524
User Action:
Complete the following steps:
1. Check the event log of XClarity Controller for any fan or cooling-related issues or power-related
issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in
place,clean, and correctly installed.
3. Make sure that the room temperature is within operating specifications.
• FQXSPCA2002I: Numeric sensor [NumericSensorElementName] going low (lower critical) has
deasserted.
This message is for the use case when an implementation has detected a Lower Critical sensor going low
has deasserted.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Critical - Fan Failure
SNMP Trap ID: 11
CIM Prefix: PLAT CIM ID: 0481
User Action:
Information only; no action is required
• FQXSPCA2007I: Numeric sensor [NumericSensorElementName] going high (upper non-critical)
has deasserted.
This message is for the use case when an implementation has detected an Upper Non-critical sensor
going high has deasserted.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Warning - Temperature
SNMP Trap ID: 12
CIM Prefix: PLAT CIM ID: 0491
User Action:
Information only; no action is required
• FQXSPCA2009I: Numeric sensor [NumericSensorElementName] going high (upper critical) has
deasserted.
This message is for the use case when an implementation has detected an Upper Critical sensor going
high has deasserted.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Critical - Temperature
SNMP Trap ID: 0
.