This message is for the use case when an implementation has detected that a Failed Array has been
Restored.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Critical - Hard Disk drive
SNMP Trap ID: 5
CIM Prefix: PLAT CIM ID: 0177
User Action:
Information only; no action is required
• FQXSPSD2007I: Array rebuild completed on drive [arg1] in the enclosure (MTM-S/N: [arg2]).
This message is for the use case when an implementation has detected that an Array Rebuild has
Completed.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: PLAT CIM ID: 0179
User Action:
Information only; no action is required
• FQXSPSD2008I: Drive [arg1] in the enclosure(MTM-SN: [arg2]) has been enabled.
This message is for the use case when an implementation has detected a Drive was Enabled.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Critical - Hard Disk drive
SNMP Trap ID: 5
CIM Prefix: PLAT CIM ID: 0167
User Action:
Information only; no action is required
• FQXSPSD2010I: Drive [arg1] in the enclosure(MTM-SN: [arg2]) has been removed.
This message is for the use case when an implementation has detected a Drive has been Removed.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: PLAT CIM ID: 0163
User Action:
Complete the following steps until the problem is solved:
1. If drive was intentionally removed, make sure that there is a filler in the drive bay.
2. Make sure that the drive is correctly seated.
100