12. Install the non-grommet end of hose #11 from outside
the cabinet in the upper drain hole. Install on collec-
tor box and secure with a silver clamp.
13. Use two silver clamps and secure the hoses to drain
trap. The trap outlet faces the front of the furnace.
Secure the trap to the cabinet using two screws re-
moved in step 2 by inserting the two screws through
the large set of holes in the top mounting tabs of the
trap into the two predrilled holes in the side of the
cabinet. [Removed: Place cap on vent...]
14. Refer to Field Supplied Drain section for instructions
on field supplied / installed drain on outlet of furnace
trap.
Upflow Model Installed Horizontally With Left
Side Down - Alternate
*Also see Front Cover Pressure Switch Tube Location
page 14.
Insert flange. Cut 2 ½" long.
R 000142
F
NOTE: In the Horizontal left installation position, a
means of condensate collection must be provided to
keep vent pip condensate from entering the draft
inducer housing. If the vent-drain elbow is elminated
from the installation; an RF000142 kit must be used.
1. (Draining the RF000142 Coupling) Locate hose #2 (fac-
tory installed). Cut off and discard the 45°radius end.
2. Install 90°radius end of hose #2 on RF000142 drain
outlet and secure with a red clamp.
3. Insert coupling in hose #2 and secure with a red
clamp.
4. Locate hose #5 and cut 3" from the non-grommet
end. Discard the section without the grommet.
5. Insert the cut end of tube #5 through the lower cabi-
net drain hole.
6. Insert 100 degree elbow in the cut end of hose #5.
7. Locate hose #6. Using red clamps, connect between
the coupling and 100 degree elbow, cutting off excess
tubing.
Figure 26
8. (Draining the Collector Box) Remove cap from left
side collector box drain port (bottom in horizontal
left position) and install it on right side (top) collector
box drain port.
9. Install the non-grommet end of hose #11 from outside
the cabinet in the upper drain hole. Install on collec-
tor box and secure with a silver clamp.
10. Use two silver clamps and secure the hoses to drain
trap. The trap outlet faces the front of the furnace.
Secure the trap to the cabinet using two screws re-
moved in step 2 by inserting the two screws through
the large set of holes in the top mounting tabs of the
trap into the two predrilled holes in the side of the
cabinet.

Counterflow Model Installed Vertically

Hose #4 x 3
The furnace drain may exit the right or left side of the
furnace cabinet (left side preferred) Trap and factory
installed hoses remain as shipped if the drain will exit
the left side of the cabinet. Draining from the right side
requires re-location of the trap to outside the cabinet.

Drain Exiting Left Side

1. Install a field supplied rubber coupling secured with a
1 1/4" clamp to enable removing the trap for future
cleaning. Alternately, a PVC fitting may be glued on
the trap outlet.
2. nstall drain per local and National codes.