7.4

Access to control box

If access inside the control box is required, remove front cover (fig 27):
▶ Remove the two screws (1) at the bottom of the control box
▶ Push down the two spring clips
▶ Pull the bottom area of the front cover forwards and carefully lift the
cover upwards to clear the two lugs at the top of the control box (2).
▶ Remove earth cable connector from tab at the inside lower edge of
the door (3)(squeeze connector lug).
Fig 28 shows the two control boards revealed within the control box
(note, cables not shown for clarity)
All cables not shown for clarity
1.
Fig. 27 Control box front cover removal
Pre plumbed cylinder – 6 721 852 928 (2023/04)
2.
3.
Earth cable
0010048544-001
XCU-
THH
Cables not shown for clarity
Fig. 28 Front view control box
Electrical connection
XCU-
SEH
0010047654-001