Download Print this page

Kenwood KDC-MP538U Service Manual page 7

Hide thumbs Also See for KDC-MP538U:

Advertisement

MICROCOMPUTER'S TERMINAL DESCRIPTION
Pin No.
Pin Name
I/O
71
ACC DET
I
72
BU DET
I
73
LX REQ S
I
74
MUTE AFS
I/O IC-2 MUTE C control / AFS mute
75
SDAEVOL
I/O Data output from system μ-COM to E-VOL
75
SDAE2P
I/O I2C data for ROM correction
76
SCLEVOL
I/O Clock output from system μ-COM to E-VOL
76
SCLE2P
I/O I2C clock for ROM correction
77
PWIC MUTE
O
78
PWIC STBY
O
79
LX REQ M
O
80
LX MUTE
I
81
LX CON
O
82
LX RST
O
83
MUTE PRE FR
O
84
MUTE PRE SW
O
85
PON AM
I/O AM+B power supply control
86
TUN IFC OUT
I
87
TUN SMETER
I
88
RDS NOISE
I
89
RDS AFS M
I/O Noise detection time constant SW
90
TYPE 1
I
91
TYPE 2
I
92,93
NC
-
94
AVSS
-
95
NC
-
96
VREF
-
97
AVCC
-
98
LX DATA S
I
99
LX DATA M
O
100
LX CLK
I/O LX-BUS clock
Truth value table
q CD motor control
CD MOTOR (Pin 40)
Standby
L
Eject
H
Load
H
Brake
H
Application
ACC detection
BU detection
Communication request from slave unit
Power IC mute
Power IC standby
Communication request to slave unit
Mute request from slave unit
Start-up request to slave unit
Forced reset to slave unit
External preout mute F/R
External preout mute SUB
(Countermeasure for mute shock noise)
Front-end IFC-OUT input
S-meter voltage detection
FM noise voltage detection
A/D (5-pattern)
A/D (5-pattern)
Not used
Not used
Data from slave unit
Data to slave unit
CD LOEJ (Pin 45)
L
H
L
Hi-z
KDC-MP538U/MP6039/MP6539U/
W6041U/W6141UY/W6541U/W6641UY/X592
Truth Value
Processing / Operation / Description
Table
ACC detected: L, No ACC: H
BU detected: L, No BU or Momentary power
down or Over-voltage: H
L: Mute ON, Hi-Z: Normal,
Time constant isolation setting: 0.5ms
Communication speed: 200k-400kHz
Communication speed: 200k-400kHz
Communication speed: 200k-400kHz
Communication speed: 200k-400kHz
STANDBY source or Momentary power down:
L, TEL mute: L
POWER ON: H, POWER OFF: L
H: Mute ON, L: Mute OFF
H: Slave unit ON, L: Slave unit OFF
H: Reset, L: Normal
0-bit, Momentary power down: L
0-bit, Momentary power down: L
H: AM received, Hi-z: Other conditions
H: Station detected, L: No station
L: AF search, Hi-Z: Normal
Output L fi xed
Output L fi xed
7

Advertisement

loading