Summary of Contents for Hyco Rho

  • Page 1 Product Instruction Manual IN44 & IN60 Instantaneous inline water heater Version 3.2 Jan 2015 V22,11/1...
  • Page 2 Thank you for purchasing a Hyco instantaneous water heater. Instantaneous water heaters are very energy efficient since they only consume energy when they are used and so have no standing losses.Bare wire heating systems offer rapid heat up times and a near instant supply of hot water.
  • Page 3 2. Installation Wall Mounting Do not install if there is a risk of water freezing in the heater. Do not install the heater where the consequences of a leak could be unusually severe. (e.g. above computer equipment). • The heater must be mounted horizontally with the inlet and outlet connections at the top of the heater.
  • Page 4 Plumbing connections The heater is designed for use with spray head type taps. Ensure the following criteria are met for the water supply: • Minimum flow = 2.0L/min • Pressure Min/Max = 0.1Mpa/0.75Mpa • Water resistivity = ≥1300 Ωcm Suitable for use with pre-heated water e.g. solar heating systems to a maximum of 60 Flush supply pipes to remove any debris before connecting the heater to the water supply.
  • Page 5 Electrical connection Do not commence electrical installation before connecting the heater to the water supply and verifying there are no leaks or air gaps. Electrical installation must be carried out by a qualified electrician in accordance with the latest edition of the IEE wiring regulations. •...
  • Page 6 3. Operation Once installed and connected to the electrical supply the heater is ready for use. The heaters have no external controls and will simply operate when a flow of higher than 2.0L/m is detected passing through the heater. Due to the nature of instantaneous heaters, water is only heated as it passes through the tank.
  • Page 7 5. Specifications IN44 IN60 Power supply 230V~ 50Hz 230V~ 50Hz Dimensions H140 x W190 x D80mm H140 x W190 x D80mm Power 4400W 6000W Protection class IPX4 IPX4 Rated current Over heat protection 800C 800C temperature Minimum operating 2.0L/Min 2.0L/Min flow rate Minimum operating 0.1MPa...
  • Page 8 If you experience a problem with this product you should first contact our service department on 01924 225 200 before taking any further action. Experience has shown that issues can often be resolved without the need to return or uninstall the product. Hyco Manufacturing Ltd Normandy Court Express Way Castleford, WF10 5NR...