INTERNAL COMPONENTS
A pressure relief device (PRD) is designed into the hand wash unit which meets European Standards. The PRD provides a level of appliance
protection should an excessive build-up of pressure occur within the unit.
DO NOT operate the appliance with a damaged spout or blocked spray plate, which can cause the PRD to operate.
1

SAFETY

IMPORTANT INFORMATION
1.1 This product is manufactured to European and British Standards and is safe and without risk, provided it is installed, used and maintained
in good working order in accordance with these instructions and recommendations.
1.2 Read all these instructions before starting work and retain them for later use.
1.3 DO NOT operate the unit if it is frozen, or suspected to be frozen. It must thaw out before using.
1.4 DO NOT operate the unit it if :-
1.
Water ceases to flow during use.
2.
Water has entered inside the unit because of an incorrectly fitted cover
3.
If the unit is damaged.
1.5 ISOLATE the electrical and water supply before removing cover.
1.6 ISOLATE electrical and water supplied before removing cover.
1.7 The unit must be mounted onto a finished wall surface (or on top of tiles).
1.8 DO NOT tile up to unit after fixing to wall
1.9 The spray plate must be cleaned when any of its holes become blocked, otherwise restriction to the flow from the outlet spout will result in
high temperatures and could also cause the PRD to operate (see 1.1 and 1.2).
1.10 The unit is not suitable for mounting into steam rooms or steam cubicles.
1.11 CAUTION. It is recommended that persons who have difficulty understanding or operating these controls should not be left unattended
when washing hands. Special consideration should be given to young children and the less able-bodied.
1.12 Only use designated entry points for cable and pipe.
PLUMBING
1.13 The plumbing installation must comply with Water Regulations.
1.14 The supply pipe must be flushed to clear debris before connecting to the handset unit.
1.15 DO NOT solder pipes or fittings within 380mm of the appliance, as heat transfer can damage components.
1.16 DO NOT FIT ANY FORM OF OUTLET FLOW CONTROL AS THE OUTLET ACTS AS A VENT FOR THE HEATER CAN.
1.17 Do not use excessive force when fitting spout fixing nut; finger tightness is sufficient.
1.18 All plumbing connections must be completed and checked for leaks before making electrical connections.
ELECTRICAL
1.19 Before fitting the unit, ensure that the consumer unit and any switches are suitable for the additional load. If in doubt, contact your
electricity supplier.
1.20 The installation must comply with BS 7671 "Requirements for electrical installations" (IEE Wiring Regulations).
1.21 CAUTION - This Appliance Must Be Earthed.
1.22 Fuses do not give personal protection against electric shock. To enhance electrical safety a 30mA residual current device (RCD) should be
installed in all electric hand wash circuits. This may be part of the consumer unit, or a separate unit.
1.23 Ensure that all terminal block connections are sufficiently tight.
1.24 Switch off appliance immediately and isolate if water ceases to flow during use.
1.25 Other electrical equipment e.g. extractor fans must not be connected to the hand wash or its supply circuit.
1.26 The appliance must be switched off at the isolating switch when not in use

2. TECHNICAL SPECIFICATIONS

2.1 CONNECTIONS
Inlet connection
-
Water entry point
-
Cable entry point
-
2.2 Electrical
3.10kw
2.85kW
Use 1.5 sq.mm . cable minimum.
2.3 Materials :
Back plate, cover and control knob - high impact Polystyrene
Heating element - copper sheathed rod-type
2.4 Dimensions
Height: 210
2.5 Standards and Approvals. Complies with the requirements of EN60335-2-35.
ULTRAWASH 3.0kW
15mm ext. diameter copper pipe.
bottom
bottom and rear
- 12.9 amps at 240 Volt .
- 12.4 amps at 230 Volt
Width: 164
NEMKO Approved
Complies with European Community Directives (CE)
Depth: 77
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ULTRAWASH 3.0kW and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Hyco ULTRAWASH 3.0kW

  • Page 1 ULTRAWASH 3.0kW ELECTRIC HANDWASH INSTALLATION AND USER INSTRUCTIONS Please read and understand these instructions before commencing installation. Please leave these instructions with the user. INTERNAL COMPONENTS A pressure relief device (PRD) is designed into the hand wash unit which meets European Standards. The PRD provides a level of appliance protection should an excessive build-up of pressure occur within the unit.
  • Page 2 4 SITE REQUIREMENTS WARNING - The hand wash must not be positioned where it may be subjected to freezing conditions. Water requirements. The installation must be in accordance with Water Regulations. To ensure activation of the heating elements, the hand wash must be connected to a water supply with a minimum running pressure of 1 Bar (14.5 psi) ands a maximum static pressure of 3 Bar (45 psi).
  • Page 3 This guarantee does not in any way affect the statutory rights of the consumer The policy of Hyco Manufacturing Ltd is one of continuous product development and as such we reserve the right to change or amend specifications with notice...

Table of Contents