Advertisement

Quick Links

Installer: Leave these instructions with the
appliance.
Consumer: Keep these instructions for future
.
reference
WARNING:
Improper installation, adjustment
alteration, service, or maintenance can
cause injury or property damage. Read the
installation, operating, and maintenance
instructions thoroughly before installing or
servicing this equipment. 
WARNING:
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
An LP-cylinder not connected for use shall
not be stored in the vicinity of this or any
other appliance. 
DANGER
CARBON MONOXIDE HAZARD
This appliance can produce carbon
monoxide which has no odor.
Using it in an enclosed space can kill
you.
Never use this appliance in an enclosed
space such as a camper, tent, car or
home.
Questions, Problems, Missing Parts? Before
returning to your retailer, call our customer
service department in the US at 1-800-416-3511,
9:00am - 5:00pm Monday – Friday, EST. English,
or you may email
customerservice@agio-usa.com.
Jul-01-2022
SAFETY MANUAL
WARNING: It is UNSAFE to use this product
for cooking!
If you smell gas:
FIRE OR EXPLOSION HAZARD
If you smell gas:
•shut off gas to the appliance.
CSA Model
•Extinguish any open flame.
WT17YL
•if odor continues, leave the area
ARY05200
immediately.
•After leaving the area, call your gas
supplier or fire department.
Failure to follow these instructions could
result in fire or explosion, which could
cause property damage, personal injury, or
death.
If the information in this manual is not
followed exactly, a fire or explosion may
result causing property damage, personal
injury, or loss of life.
Installation and service must be performed
by a qualified installer, service agency, or
the gas supplier.
FOR USE WITH 9KG (20LB) PROPANE
CYLINDER WITH TYPE 1 CONNECTION OR
FOR USE WITH NATURAL GAS AFTER
CONVERSION KIT IS INSTALLED (MUST BE
PROFESSIONALLY INSTALLED).
1
1
DANGER
WARNING:
WARNING:For Outdoor Use Only.
WARNING:
USE FACTORY APPROVED
REPLACEMENT PARTS AND
ACCESSORIES ONLY. USE OF
UNAPPROVED PARTS OR
ACCESSORIES CAN VOID
THE WARRANTY ON THIS
PRODUCT AND RESULT IN A
HAZARDOUS CONDITION.
PLEASE CONTACT US FOR
INFORMATION REGARDING
REPLACEMENT HOSES,
THERMOCOUPLES,
ELECTRODES, IGNITION
MODULES, LAVA ROCKS,
LOGS, FIRE ICE, ETC.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ARY05200 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Backyard Creations ARY05200

  • Page 1 •shut off gas to the appliance. CSA Model •Extinguish any open flame. WT17YL •if odor continues, leave the area ARY05200 immediately. •After leaving the area, call your gas supplier or fire department. Installer: Leave these instructions with the Failure to follow these instructions could appliance.
  • Page 2 TABLE OF CONTENTS Important Safety Information ................ 3 Important Information about Propane ............4 Specification ....................4 Natural Gas Conversion ................5-6 Maintenance ....................6 Batteries ....................... 7 Lighting Instructions ..................7 Troubleshooting Guide ................. 8...
  • Page 3 IMPORTANT SAFETY INFORMATION The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54; International Fuel Gas Code. ; Natural Gas and Propane Installation Code, CSA B149.1; or Propane Storage and Handling Code, B149.2, as applicable. The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5kPa).
  • Page 4 IMPORTANT SAFETY INFORMATION ABOUT PROPANE (LP) GAS A LP-gas cylinder for use with this appliance must have a capacity of 20 lbs / 9kg (See recommended tank size on Figure 1a) and must be equipped with a Type 1 connector and an OPD (overfill protection device). Figure 1b. The LP-gas supply cylinder to be used must be constructed and marked in accordance with the specification for LP-gas cylinders of the U.S.
  • Page 5 NATURAL GAS CONVERSION Natural gas conversion must be performed only by your natural gas provider or service company. 1. SHUT OFF THE GAS SUPPLY TO THE UNIT AND ANY NEARBY ELECTRICAL SOURCE OR APPLICANCES 2. Below the burner, carefully disconnect flex connector attached to the orifice holder (see step1).
  • Page 6 9. Restore your gas supply and check ALL of the connections for leaks using a solution of soapy water. If a leak is discovered and any bubbles are seen, close the main gas valve and re-tighten ALL the connections. NEVER USE A FLAME TO CHECK FOR GAS LEAKS! Step5 10.
  • Page 7 BATTERIES Make sure the control knob is in the "OFF" position. Unscrew the push button cap on the ignition module located on the control panel to access the battery compartment. The ignition module requires one Alkaline AA size battery (1.5V). The negative (-) end goes in first. See Figure 5.
  • Page 8 TROUBLESHOOTING GUIDE PROBLEM CAUSE REMEDY Check that gas tank valve is open. Turn the control knob No Propane Gas at Burner to “ON” and push the control knob in. Make sure tank has propane gas. Check that AA battery is installed with negative (-) end first and has a charge.

This manual is also suitable for:

Wt17yl