Page 2
E26.0.01.6C-07 Operating Manual GTH 2448 / 1 Page 2 of 6 _____________________________________________________ _____________________________________________________________________________ CONTENTS GENERAL NOTE ..............................3 SAFETY ..................................3 ..............................3 NTENDED ..........................3 AFETY SIGNS AND SYMBOLS ............................3 AFETY GUIDELINES SCOPE OF SUPPLY ..............................4 ELECTRIC CONNECTION ............................. 5 CORRECTION TABLE ............................
Page 3
E26.0.01.6C-07 Operating Manual GTH 2448 / 1 Page 3 of 6 _____________________________________________________ _____________________________________________________________________________ 1 General Note Read this document carefully and get used to the operation of the device before you use it. Keep this document within easy reach near the device for consulting in case of doubt. Mounting, start-up, operating, maintenance and removing from operation must be done by qualified, specially trained staff that have carefully read and understood this manual before starting any work.
Page 4
E26.0.01.6C-07 Operating Manual GTH 2448 / 1 Page 4 of 6 _____________________________________________________ _____________________________________________________________________________ 3. When connecting the device to other devices the connection has to be designed most thoroughly as internal connections in third-party devices (e.g. connection GND with protective earth) may lead to undesired voltage potentials that can lead to malfunctions or destroying of the device and the connected devices.
Page 5
E26.0.01.6C-07 Operating Manual GTH 2448 / 1 Page 5 of 6 _____________________________________________________ _____________________________________________________________________________ 4 Electric Connection Electric connections for the GTH 2448 / 1 are located at the back of the device. Connection is made via screw-type/plug-in terminals (max. terminal range 1,5mm²). Make it a rule to always mount screw-type/plug-in terminals while they are still loose and connect only later.
Page 6
E26.0.01.6C-07 Operating Manual GTH 2448 / 1 Page 6 of 6 _____________________________________________________ _____________________________________________________________________________ 6 Specifications -50 … +1150 °C Measuring range: Resolution: 1 °C Probe connection: NiCr-Ni, (probe not included in scope of supply) Accuracy: < 1 % ± Digit (from -20 to +550°C and 920 to 1150°C); <...