Gas Tightness And Inlet Pressure (Remote Control Models) - Flavel Richmond Plus FOPC MN Series Installation, Maintenance & User Instructions

Inset live fuel-effect gas fires
Table of Contents

Advertisement

2.5
GAS TIGHTNESS AND INLET PRESSURE - REMOTE CONTROL
MODELS
2.5.1
Remove the pressure test point screw from the inlet elbow and fit a
manometer.
2.5.2
Turn on the main gas supply and carry out a gas tightness test.
2.5.3
Light the fire, see page 27 to 30 for full details of the operating method
for the fire.
Check that the gas pressure is 20.0 mbar (+/- 1.0mbar) 8.0 in w.g.(+/-
2.5.4
0.4 in w.g.)
2.5.5
Turn off the fire, remove the manometer and refit the pressure test point
screw. Check the pressure test point screw for gas tightness with the
appliance turned on using a suitable leak detection fluid or detector.