Aqua Lung CALYPSO Maintenance Manual page 17

Second stage
Hide thumbs Also See for CALYPSO:
Table of Contents

Advertisement

Calypso/Titan Second Stage Service Manual
PART NUMBER
APF124563/APF124566
104106
TEST
Leak Test
Opening Effort
Flow effort
Purge flow
Table 5 - Torque Specifi cations
DESCRIPTION / KEY NUMBER
LP Hose Female Fitting (25)
Inlet Fitting (13)
Table 6 - Test Bench Specifi cations
CONDITION
Inlet 2,500-3,000 (±100) psig
Inlet 2,500-3,000 (±100) psig
Intermediate pressure 135-140 psi
Intermediate pressure 135-140 psi at
14 SCFM
Intermediate pressure 135-140 psi
TORQUE
40±3 inch-lbs
45±5 inch-lbs
ACCEPTABLE RANGE
No leaks allowed
Calypso/Titan: +1.0 - 1.6 in. H
Octopus: +1.2 - 1.8 in. H
+6 in. H
0 (maximum)
2
12 SCFM flow rate
17
0
2
0
2

Hide quick links: