EINHELL ROYAL MSB 34 Operating Instructions Manual page 24

Petrol power scythe
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 18
Anleitung MSB 34_SPK1:Anleitung BHS 26_D
GB
13. Troubleshooting
Fault
The machine does not start.
Correct starting procedure not
followed.
Sooted or damp spark plug
Incorrect carburetor setting
The machine starts but does not
Incorrect choke lever setting
develop its full output.
Soiled air filter
Incorrect carburetor setting
The engine does not run smoothly
Incorrect electrode gap on the
spark plug
Incorrect carburetor setting
Engine smokes excessively
Incorrect fuel mix
Incorrect carburetor setting
24
07.12.2006
All manuals and user guides at all-guides.com
Possible cause
Troubleshooting
Follow the instructions for starting.
Clean the spark plug or replace it
with a new one.
Contact an authorized customer
service outlet or send the machine
to ISC-GmbH.
Set choke lever to
Clean the air filter
Contact an authorized customer
service outlet or send the machine
to ISC-GmbH.
Clean the spark plug and adjust
the electrode gap or fit a new spark
plug.
Contact an authorized customer
service outlet or send the machine
to ISC-GmbH.
Use the correct fuel mix (see fuel
mixing table)
Contact an authorized customer
service outlet or send the machine
to ISC-GmbH.
9:00 Uhr