1. The slit direction should be upward.
2. It should be sealed with vinyl tape
without any gap.
3. Do not over tighten with vinyl tape.
Wrap vinyl tape with the slit of the heat insulation pipe cover facing up so that there are no gap . If there is a gap or if
it is tightened too much, it may cause condensation or water dripping.
-/-
Heat insulation pipe cover
This illustration shows the case of the left rear piping.
Sectional view
wire
Insulation tape
� WARNING---------------
Fill the gap from both the indoor side and the outdoor side to
prevent dew condensation,misdetection of indoor temperature,
and invasion of small animals.
Binding Of Insulation Pipe
__ 1
-1-
Slit
Slit
Drain hose
Heat Insulation pipe cover
Sectional view
Heatlnsulation�""""
Communicltilllirl
D
��,
GMplpe
q
r I I I I
1 1 I I I ]
1_=:t:
Vinyl tape
- Overwrap more than half of heat insulation tape.
- Wrap the heat insulation tape around all the
pipes from the right side to the left side of the
pipe that pass through the back side of indoor
unit.
Seal with putty or caulking material.
­
Wall cap
'"
ln!!LMlion
.�n"::l.
.111,botlom.)
"'1)'11ope
-
Putty or caulking
material.
Sleeve
8