3. Feed the conduit and wires through the back of the charging station,
removing the back head plug. Feed the cables through the back of
the charging station until the silver conductors are no longer visible.
Note: If installing the charging station outdoors and using the back
opening to route the conduit, apply liquid sealant or a gasket and
nut around the rear opening to prevent water ingress.
4. Inside the wiring access panel, there are two terminal blocks.
Securely insert wires into the left-hand terminal block as indicated
by the wiring diagram below.
L - Brown Wire
PE (Ground) - Green/Yellow Wire
L
PE
N
N (Neutral) - Blue Wire