Table of Contents Table of Contents Safety Instructions ..........6 Declaration of Conformity ............9 Overview of this Manual ........10 Shortcuts to Major Operations ..........10 Summary of Each Chapter ............11 Specifications and Appearance ......13 Specifications ................. 13 Front Panel ................15 Rear Panel ................
Page 4
SFG-830 Service Manual List of Equipments ..............39 Verification Log ...............40 Clock Output ................44 Frequency Doubler ..............45 D/A Reference .................46 Amplitude (100Hz)..............47 Amplitude (10kHz) ..............48 Amplitude (500kHz - 1) ............49 Amplitude (500kHz - 2) ............50 Filter..................51 Harmonic Distortion..............52 Frequency Accuracy ..............53 Sine Wave Amplitude (3.54Vrms) ..........53...
Page 5
Table of Contents Troubleshooting the Instrument ......73 List of Equipments ..............74 List of Equipments ..............74 System Block Diagram ............. 75 Operation Theory ..............76 DDS Technology Overview............78 PCB Locations ................. 79 Block Diagram................. 81 RS-232C/GPIB PCB (FG01P010-3, FG01P020, FG01P060) ... 82 DC Power Supply PCB (FG01P020) ..........
SFG-830 Service Manual AFETY NSTRUCTIONS Safety Symbols WARNING CAUTION Safety Guidelines General guidelines CAUTION...
Page 7
Safety Instructions (Note) EN 61010-1:2001 specifies the measurement categories and their requirements as follows. This instrument falls under category II. Measurement category IV is for measurement performed at the source of low-voltage installation. Measurement category III is for measurement performed in the building installation. Measurement category II is for measurement performed on the circuits directly connected to the low voltage installation.
Page 8
SFG-830 Service Manual however, a temporary conductivity caused by condensation can be expected. Pollution degree 3: Conductive pollution occurs, or dry, non-conductive pollution occurs which becomes conductive due to the expected condensation. In such conditions, while the equipment is normally protected against exposure to direct sunlight, precipitation, and strong draughts, neither temperature nor humidity is controlled.
Type of Product: Arbitrary Signal Generator Model Number: SFG-830/SFG-830G are herewith confirmed to comply with the requirements set out in the Council Directive on the Approximation of the Law of Member States relating to Electromagnetic Compatibility (2004/108/EC, 89/336/EEC, 92/31/EEC, 93/68/EEC) and Low Voltage Directive (73/23/EEC, 93/68/EEC).
SFG-830 Service Manual VERVIEW OF THIS ANUAL Shortcuts to Major Operations I want to… Go to… Page Learn how to set the instrument and operate it Verify the specifications of the instrument Verify the specifications and adjust the instrument Disassembly the...
Overview of this Manual Summary of Each Chapter Safety Instructions (page6) Overview of this Manual (page10) Specifications and Appearance (page13) Setting up and Operating the Instrument (page15) Calibrating the instrument (page21) Verifying and Adjusting the...
Page 12
SFG-830 Service Manual instrument (page34) Changing the Options (page53) Disassembling the instrument (page65) Troubleshooting the instrument (page73) Ordering the Parts (page96)
Specifications and Appearance PECIFICATIONS AND PPEARANCE Specifications ................. 13 Front Panel ................15 Specifications Output Function Sine, Triangle, Ramp, Square, Sync Output, Arbitrary Wave Frequency Range Sine 20mHz to 30MHz Square 20mHz to 30MHz Triangle 100mHz to 100kHz Ramp 100mHz to 100kHz Frequency Sine 20mHz...
Page 14
SFG-830 Service Manual Square Output Rise/Fall Time 15ns Overshoot 5% (at full scale output) Asymmetry 1% of period + 4ns Triangle and Ramp Linearity 0.1% of full scale output Output Arbitrary Sample Rate 42.949600MHz / N, N = 8, 10, 12……2...
Specifications and Appearance Front Panel Power button Turns the instrument on or off. Unit keys In the ‘Normal’ mode, the Unit keys assign the unit and set the entered value. In the ‘Store’ or ‘Recall’ mode, the Unit keys work as ‘Enter’ keys.
Page 16
SFG-830 Service Manual keys, refer to the user manual. Modification Set the size and step mode, increasing or decreasing. keys Function keys Control the output functions. [ <] and [ >] keys select the output signal from arbitrary wave (ARB), sine wave, triangle wave, etc.
Setting up and Operating the Instruments Rear Panel AC socket Accepts the AC input within line voltage±10%, 50/60Hz. EXT AM Accepts external amplitude modulation input. The modulation modulation index is 100% at ±5V input. The input BNC input resistance is 100k . Sweep / Outputs the modulated waveform that is synchronous with Modulation...
SFG-830 Service Manual ETTING UP AND PERATING NSTRUMENTS Setting up the Instrument ............18 Operating the Instrument ............19 Setting up the Instrument Checking the AC rating Connecting the power cord Turning the power...
Setting up and Operating the Instruments Operating the Instrument Selecting the output function Setting the output (Example) frequency Setting the output (Example) amplitude Setting up the DC (Example) offset Displaying the sweep frequency Recalling the default status...
Page 20
SFG-830 Service Manual Setting up the ARB compiler Displaying the last received ASCII data Recalling the GPIB settings Selecting the GPIB address Switching from the remote mode to local mode Turning on the RS-232C Switching cursor point in ARB compiling mode...
SFG-830 Service Manual Preparing for Calibrations Note Calibration items When to run calibrations Calibration Environments Calibration procedure Default settings List of Equipments Item Requirements Recommended Voltmeter (Multimeter) Oscilloscope Distortion meter...
Calibrating the Instruments Entering the Calibration Mode Entering the calibration mode (Display) (Calibration ID) (Value) Moving the cursor Changing the calibration ID or value...
Calibrating the Instruments Attenuator Accepted range Value Value Equipment Configurations Calibration procedure Calibrating the attenuator is completed: move to the next step.
SFG-830 Service Manual Sine Wave Amplitude Accepted range Even ID Value Odd ID Value 114 to 115 to Equipment Configurations Calibration procedure Calibrating the sine wave amplitude is completed: move to the next step. Square Wave Amplitude Accepted range Value...
Calibrating the Instruments Triangle Wave Amplitude Accepted range Value Equipment Configurations Calibration procedure Calibrating the triangle wave amplitude is completed: move to the next step. Square Wave Symmetry Accepted range Value Value 406 to 437 438 to 460 461 to 486 487 to 502 Equipment Configurations...
SFG-830 Service Manual DC Gain and Offset Accepted range Value 503 (Sine wave) 504 (Square wave) 505 (Triangle wave) 506 to 602 (Offset) Equipment Configurations Calibration procedure Calibrating the DC gain and offset are completed. This concludes the calibration.
SFG-830 Service Manual Preparing for Verifications Note Verification and adjustment items When to run verifications Verification Environments Verification procedure Default settings...
Verifying and Adjusting the Instruments List of Equipments Item Requirements Recommended Voltmeter (Multimeter) Frequency Counter (Multimeter) Oscilloscope Spectrum analyzer Distortion meter Phillips screwdriver Minus screwdriver...
SFG-830 Service Manual Verification Log Clock output Item Min limit Result Max limit Pass/Fail Output frequency 10MHz-20Hz _______MHz 10MHz+20Hz Pass Fail Frequency doubler Item Min limit Result Max limit Pass/Fail U303 pin6 output __________ Pass Fail D/A reference Item Min limit...
Page 41
Verifying and Adjusting the Instruments Amplitude (500kHz-2) Item Min limit Result Max limit Pass/Fail Square wave __________ 5% overshoot Pass Fail Filter Item Min limit Result Max limit Pass/Fail Ripple __________ Pass Fail Harmonic distortion Item Min limit Result Max limit Pass/Fail Distortion __________...
Page 43
Verifying and Adjusting the Instruments Harmonic distortions ( 100kHz) Item Min limit Result Max limit Pass/Fail 100Hz sine wave _______dBc Pass Fail 1kHz sine wave _______dBc Pass Fail 10kHz sine wave _______dBc –50dBc Pass Fail 50kHz sine wave _______dBc Pass Fail 100kHz sine wave _______dBc...
SFG-830 Service Manual Clock Output Accepted range Equipment Configurations Verification procedure X202 location: Top PCB Close-up Verifying/adjusting the clock output is completed...
Verifying and Adjusting the Instruments Frequency Doubler Accepted range Equipment Configurations Verification procedure SVR301 location: Top PCB Close-up Verifying/adjusting the frequency doubler is completed...
SFG-830 Service Manual D/A Reference Accepted range Equipment Configurations Verification procedure SVR201 location: Top PCB Close-up Verifying/adjusting the D/A reference is completed...
Verifying and Adjusting the Instruments Amplitude (100Hz) Accepted range Equipment Configurations Verification procedure SVR604 location: Bottom PCB Close-up Verifying/adjusting the Amplitude (100Hz) is completed...
Verifying and Adjusting the Instruments Filter Accepted range Equipment Configurations Verification procedure SVC301, 302, 303, 304 location: Top PCB Close-up Verifying/adjusting the Filter is completed...
SFG-830 Service Manual Harmonic Distortion Accepted range Equipment Configurations Verification procedure SVR501, 603 location: Top PCB Close-up Verifying/adjusting the Harmonic Distortion is completed...
Verifying and Adjusting the Instruments Frequency Accuracy Accepted range Equipment Configurations Verification procedure Verifying the Harmonic Distortion is completed Sine Wave Amplitude (3.54Vrms) Accepted range Equipment Configurations Verification procedure Verifying the Sine wave amplitude (3.54Vrms) is completed...
SFG-830 Service Manual Sine Wave Amplitude (1Vrms) Accepted range Equipment Configurations Verification procedure Verifying the Sine wave amplitude (1Vrms) is completed Square Wave Amplitude Accepted range Equipment Configurations Verification procedure Verifying the Square wave amplitude is completed...
Verifying and Adjusting the Instruments Triangle Wave Amplitude Accepted range Equipment Configurations Verification procedure Verifying the Triangle wave amplitude is completed DC Offset Accuracy Accepted range Equipment Configurations Verification procedure Verifying the DC offset is completed...
SFG-830 Service Manual Sub-Harmonics Accepted range Equipment Configurations Verification procedure Verifying the Sub-harmonics is completed Harmonic Distortions ( 100kHz) Accepted range Equipment Configurations Verification procedure Verifying the Harmonic distortions ( 100kHz) is completed...
Verifying and Adjusting the Instruments Harmonic Distortions ( 500kHz) Accepted range Equipment Configurations Verification procedure Verifying the Harmonic distortions ( 500kHz) is completed Phase Noise Accepted range Equipment Configurations Verification procedure Verifying the Phase Noise is completed...
SFG-830 Service Manual Square Wave Rise Time Accepted range Equipment Configurations Verification procedure Verifying the Square wave rise time is completed Square Wave Symmetry Accepted range Equipment Configurations Verification procedure Verifying the Square wave symmetry is completed...
Verifying and Adjusting the Instruments AM Envelope Distortion Accepted range Equipment Configurations Verification procedure Verifying the AM envelope distortion is completed Remote Control Settings Accepted range Equipment Configurations Verification procedure Verifying the remote control settings is completed...
SFG-830 Service Manual HANGING THE PTIONS List of Equipments ..............60 Installing/Removing the GPIB Module ........61 Changing the AC Mains Voltage ..........62 Replacing the Mains Fuse ............63 Replacing the Internal Fuse ............64 List of Equipments Item Requirements Used in Phillips screwdriver...
SFG-830 Service Manual Replacing the Internal Fuse WARNING Rating Procedure (F101/F102) Procedure (F103/F104) Replacing the internal fuses is completed...
Disassembling the Instrument ISASSEMBLING THE NSTRUMENT List of Equipments ..............65 Top Outer Casing ..............66 Top PCB.................. 68 Bottom Outer Casing ............... 69 Bottom PCB ................71 Power Supply PCB ..............72 List of Equipments Item Requirements Used in Phillips screwdriver Minus screwdriver Plier...
SFG-830 Service Manual List of Equipments Item Requirements Used in Digital Multimeter Electronic Load Phillips screwdriver Minus screwdriver Plier Soldering kit...