Troubleshooting
Troubleshooting
Phenomenon
Indicator lamps do not light up
PM2.5 sensor lamp remains orange or
red
The PM2.5 sensor lamp is always blue
and does not change
The PM2.5 concentration value
displayed with the AIR MONITOR
indicator is always "--", and Daikin
eye remains blue and does not
change.
There is an odour but the odour
sensor lamp remains blue
The Streamer lamp blinks
Sometimes the Streamer lamp does
not light up
The Streamer lamp blinks even
though the Streamer unit has been
replaced
35
• Is the indicator lamp brightness set to OFF?
¼ To turn the lamps on, please set the indication lamp brightness to
BRIGHT or DIM.
►Page 11
• Is there a buildup of dust in or around the air intake of the PM2.5
sensor or the surrounding area?
¼ Vacuum off any dust from the air intake using a vacuum cleaner.
• Is the cover detached from the air intake for the PM2.5 sensor?
¼ Securely attach the cover.
• Is the lens for the PM2.5 sensor dirty?
¼ Wipe off dirt from the lens using a dry cotton bud or similar.
• Is any of the pre-filter dirty?
¼ Clean these parts.
►Page 27
• If the displayed value remains "--" even after you set the AIR MONITOR
indicator to display the concentration of PM2.5, the PM2.5 sensor may be
defective.
¼ Contact the place of purchase.
• Did an odour already exist around the time you inserted the power
supply plug?
¼ The basic sensitivity of the odour sensor will be determined by odour
levels in the first minute (approx.) after the power supply plug is inserted
every time.
►Page 10
To adjust the basic sensitivity of the odour sensor, unplug the power supply
when the air is clean (odour-free), wait at least 5 seconds, then re-insert the
power supply plug and turn the unit on again. This process adjusts the
reference odour level that determines the sensitivity of the odour sensor.
• Please replace the Streamer units.
¼ Contact the place of purchase.
• Depending on the degree of air impurity, Streamer operation may turn OFF.
►Page 22
• The Streamer lamp turns off when Streamer operation is OFF.
• Is Streamer output set to Low?
¼ If it is set to Low, the length of time the Streamer operates will be shorter
than when Streamer output is set to Normal.
• Is the unit operating in ECONO MODE?
¼ The Streamer lamp does not light up when the unit is in Monitoring mode
during ECONO MODE.
• After replacement, was the power supply plug inserted while pressing
FAN setting button on the unit?
• Is the Streamer unit's connector properly installed?
[In case of improper installation]
¼ Unplug the power supply, re-attach the connector, and attempt operation
again.
►Page 30
[In case of proper installation]
An electrical part is faulty.
¼ Contact the place of purchase.
Check points
►Page 27
►Page 30
►Page 21, 22
►Page 25, 26
►Page 30
►Page 27
►Page 27