Configuration Wizard; Configuration Wizard: Language; Configuration Wizard: Time And Date; Configuration Wizard: System - Daikin ETBH16EF6V Installation Manual

Hide thumbs Also See for ETBH16EF6V:
Table of Contents

Advertisement

1 Go to [B]: User profile.
B
User profile
2 Enter the applicable pin code for the user permission
level.
▪ Browse through the list of digits and change the
selected digit.
▪ Move the cursor from left to right.
▪ Confirm the pin code and proceed.
Installer pin code
The Installer pin code is 5678. Additional menu items and
installer settings are now available.
Installer
5678
Advanced user pin code
The Advanced user pin code is 1234. Additional menu items for the
user are now visible.
Advanced user
1234
User pin code
The User pin code is 0000.
User
0000
To access the installer settings
1 Set the user permission level to Installer.
2 Go to [9]: Installer settings.
To modify an overview setting
Example: Modify [1‑01] from 15 to 20.
Most settings can be configured via the menu structure. If for any
reason it is required to change a setting using the overview settings,
then the overview settings can be accessed as follows:
1 Set the user permission level to Installer. See
change the user permission
2 Go to [9.I]: Installer settings > Overview
field settings.
ETBH/X16EF6V+9W
Daikin Altherma 3 H HT W
4P644727-1 – 2021.02
"To
level" [ 4  20].
3 Turn the left dial to select the first part of the setting
and confirm by pressing the dial.
00
05
0A
01
06
0B
0
1
02
07
0C
2
03
08
0D
3
04
09
0E
4 Turn the left dial to select the second part of the
setting
00
05
0A
01 15
06
0B
1
02
07
0C
03
08
0D
04
09
0E
5 Turn the right dial to modify the value from 15 to 20.
00
05
0A
01 20
06
0B
1
02
07
0C
03
08
0D
04
09
0E
6 Press the left dial to confirm the new setting.
7 Press the center button to go back to the home
screen.
INFORMATION
When you change the overview settings and you go back
to the home screen, the user interface will show a popup
screen and request to restart the system.
When confirmed, the system will restart and recent
changes will be applied.
7.2

Configuration wizard

After first power ON of the system, the user interface will guide you
using the configuration wizard. This way you can set the most
important initial settings. This way the unit will be able to run
properly. Afterwards, more detailed settings can be done via the
menu structure if required.
7.2.1

Configuration wizard: Language

#
Code
[7.1]
N/A
Language
7.2.2

Configuration wizard: Time and date

#
Code
[7.2]
N/A
Set the local time and date
INFORMATION
By default, daylight savings time is enabled and clock
format is set to 24 hours. If you want to change these
settings, you can do this in the menu structure (User
settings > Time/date) once the unit is initialised.
7.2.3

Configuration wizard: System

Indoor unit type
The indoor unit type is displayed, but cannot be adjusted.
7 Configuration
Description
Description
Installation manual
21

Advertisement

Table of Contents
loading

This manual is also suitable for:

Altherma 3 h ht wEtbh16ef9wEtbx16ef6vEtbx16ef9w

Table of Contents