Deactivation; False Alerts - Ocean Signal EPIRB2 Pro User Manual

Emergency position indicating radio beacon with rls
Hide thumbs Also See for EPIRB2 Pro:
Table of Contents

Advertisement

5.3

Deactivation

5.3.1 Deactivation if Manually Activated
If the EPIRB2 Pro has been inadvertently activated or the emergency situation has passed,
it can be turned off simply by pressing and holding for 1 to 2 seconds the ON/OFF
is not possible for the user to replace the red protective cover. Return the EPIRB2 Pro to an
Ocean Signal authorised service centre for checking and replacement.
5.3.2 Deactivation if Automatically Activated
If the EPIRB2 Pro was automatically activated by placing in water, remove from the water
and dry. The EPIRB2 Pro will automatically switch off after approximately 30 seconds.
6.

FALSE ALERTS

False alerts are a serious problem - they cause valuable resources to be diverted away
from real emergency situations. If a false alert is initiated, by any means, it is important to
contact the nearest search and rescue authority and inform them of the false alert.
Report the following information:
1.
EPIRB2 Pro Hex ID.
2.
Date, time and duration.
3.
Cause of activation.
4.
Location when the alert was activated.
5.
Location at time of deactivation.
If the EPIRB2 Pro was activated by mistake then turn it off. The first emergency trans-
mission will not occur for approximately 50 seconds. If the unit is turned off within this time
then EPIRB2 Pro will not have sent an emergency distress alert.
The EPIRB2 Pro is fitted with water activation contacts. Although the Auto Release Housing
is designed to prevent accidental activation in heavy seas and adverse weather conditions,
if the EPIRB2 Pro is not correctly fitted in its housing it is possible that this may cause a
false alert situation.
If the unit has been dropped into the water then remove from the water and dry the case.
Wait approximately 30 seconds for the water contacts to de-activate. If the unit is still
flashing after this period, check that the unit has not been manually activated; if so then
follow the procedure to manually switch the EPIRB2 Pro off.
Once the EPIRB2 Pro is switched off, it is advisable to carry out a self test before replacing
the EPIRB2 Pro into the Auto Release Housing.
Should the EPIRB2 Pro fail to deactivate, bend the antenna down and completely
!
wrap in several layers of aluminium foil , or place in a metal container with a
tightly fitting lid.
20
EPIRB2 Pro USER MANUAL
912S-04393 - 01.00
key. It
22/05/2023

Advertisement

Table of Contents
loading

Table of Contents