TYPICAL UNDER COUNTER INSTALLATION OF AN ELECTRIC BUILT-IN
WARNING!
To reduce the risk of personal
injury and tipping of the wall
oven, the wall oven must be
secured to the cabinet (s) by
mounting brackets.
208/240 Volt
junction box for
built-in oven.
OVEN SIZE
30"
(76.2 cm)
8
OVEN WITH A COOKTOP MOUNTED ABOVE
Only certain cooktop models may be
installed over certain built-in electric
oven models. Approved cooktops and
built-in ovens are listed by the MFG
ID number and product code (see the
insert sheet included in the literature
package and cooktop installation
instructions for the dimensions).
Approx. 3"
(7.5 cm)
5"
(12.5 cm) Max.
CUTOUT DIMENSIONS
F. WIDTH
Min.
Max.
28 ½"
29"
(72.4 cm)
(73.7 cm)
G
F
Cut an opening in wood base minimum
9" x 9" (23 X 23 cm), 2" (5 cm) from left
side filler panel, to route armoured cable
to junction box.
G. DEPTH
Min.
23 ½"
(59.7 cm)
Figure 3
Cabinet side filler panels are
necessary to isolate the unit
from adjoining cabinets. Cabinet
side filler height should allow for
installation of approved cooktop
models
35 ¾" Min.
(90.8 cm) Min.
H
Use 3/4" (1.9 cm) plywood, installed
on two runners, flush with toe plate.
Base must be capable of supporting
200 pounds (90 kg).
H. HIGHT
Min.
Max.
27 ¼"
28 ½"
(69.2 cm)
(72.4 cm)
AA-2328607-1