Remote operation
NOTICE
Shutdown
Page 28
In remote mode, the Extraction and Filtration System
LAS 260.1 can be controlled by a higher-level machine via the
communication interface M12.
The higher-level machine can then switch on the LAS 260.1
and set it into standby mode.
Prerequisite for remote operation:
The higher-level machine is connected via the
-
communication interface M12 to the LAS 260.1.
S2 switch is in the position "0"
-
The operator can still adjust the suction power by hand on the
potentiometer and switch on the ecoflow CS
(see section ecoflow CS
If no higher-level machine is connected, the S2 switch must be
in the position "I."
The time interval between switching on and switching off
should be at least 5 minutes. Otherwise, there is a risk that the
blower might be damaged.
When shutting down the LAS 260.1, always follow the safety
instructions in these operating instructions.
-
Switch off the unit.
-
Disconnect the electrical connections of the LAS 260.1.
Shutdown
®
®
).
LAS 260.1 – Date 07/2023
via the S3 switch