Sharp R-933 Service Manual page 29

Microwave oven with grill and convection
Table of Contents

Advertisement

COMPONENT REPLACEMENT AND ADJUSTMENT PROCEDURE
1. CARRY OUT 3D CHECKS.
2. Disconnect the main wire harness from the high volt-
age transformer.
3. Disconnect the filament leads and high voltage wire of
high voltage transformer from high voltage capacitor
and the magnetron.
1. CARRY OUT 3D CHECKS.
2. Disconnect the H.V. wire B and filament lead of the
transformer from the magnetron.
3. Carefully remove three (3) screws holding the
magnetron to the waveguide, when removing the screws
hold the magnetron to prevent it from falling.
4. Remove the one (1) screw holding the magnetron to
the chassis support.
5. Remove the magnetron from the waveguide with care
so the magnetron antenna is not hit by any metal object
1. CARRY OUT 3D CHECKS.
2. Disconnect the wire leads and the connectors from the
control unit.
3. Remove the one (1) screw holding the earth wire to the
oven cavity face plate.
4. Remove the one (1) screw holding the jog panel to the
oven cavity face plate.
5. Lift up the control panel assembly and pull it forward.
Now the control panel assembly is free.
Jog and Switch unit
6. Disconnect the connector CN-G from the CPU unit.
7. Remove the one (1) screw holding the LCD holder to
REMOVAL
1. CARRY OUT 3D CHECKS.
2. Remove the one (1) screw holding the noise filter to the
chassis support.
3. Release the noise filter from the tabs of the fan duct.
4. Remove the three (3) screw holding the chassis sup-
port to the oven cavity front flange, back plate and the
magnetron.
5. Remove the chassis support from the oven cavity.
6. Disconnect the wire leads from the fan duct.
7. Remove the one (1) screw holding the fan duct to the
back plate.
8. Release the tabs of the fan duct from back plate.
9. Remove the fan duct from the oven.
10.Remove the fan blade from the fan motor shaft accord-
ing to the following procedure.
1) Hold the edge of the rotor of the fan motor by using
a pair of groove joint pliers.
CAUTION:
• Make sure that no swarf from the rotor enters
the gap between the rotor & stator of the fan
motor.
• Avoid touch the coil of the fan motor with the
pliers as the coil may become cut or damaged.
• Avoid deforming the bracket whilst using the
pliers.
2) Remove the fan blade assembly from the shaft of
the fan motor by pulling and rotating the fan blade
with your hand.
HIGH VOLTAGE TRANSFORMER REMOVAL
MAGNETRON REMOVAL
CONTROL PANEL ASSEMBLY REMOVAL
FAN MOTOR REPLACEMENT
4. Remove the two (2) screws and one (1) washer holding
the transformer to the base plate.
5. Remove the transformer.
6. Now the high voltage transformer is free.
around the antenna.
6. Remove the magnetron guide H from the magnetron.
7. Remove the one (1) screw holding the magnetron
guide V to the magnetron.
8. Now, the magnetron is free.
CAUTION: WHEN REPLACING THE MAGNETRON,
BE SURE THE R.F. GASKET IS IN PLACE
AND THE MAGNETRON MOUNTING
SCREWS ARE TIGHTENED SECURELY.
the jog panel.
8. Remove the four (4) screws holding the power unit to
the jog panel.
9. Remove the control unit assembly (CPU unit and
Power unit) from the jog panel.
10.Remove the six (6) screws holding the jog and switch
unit to the jog panel.
11.Remove the jog and switch unit from the jog panel.
12.Remove the select knob and the time knob from the jog
and switch unit.
13.Now, the jog and switch unit is free.
3) Now, the fan blade is free.
CAUTION:
• Do not re-use the removed fan blade as the
fixing hole may be oversize.
11.Remove the two (2) screws holding the fan motor to the
fan duct.
12.Now, the fan motor is free.
INSTALLATION
1.
Install the fan motor to the fan duct
with the two (2) screws and nuts.
2. Install the fan blade to the fan motor shaft according to
the following procedure.
1) Hold the centre of the bracket which supports the
shaft of the fan motor on a flat table.
2) Apply the screw lock tight into the hole (for shaft) of
the fan blade.
3) Install the fan blade to the shaft of fan motor by
pushing the fan blade with a small, light weight, ball
peen hammer or rubber mallet.
CAUTION:
• Do not hit the fan blade when installing be-
cause the bracket may be deformed.
• Make sure that the fan blade rotates smoothly
after installation.
• Make sure that the axis of the shaft is not
slanted.
27