Components
Upper oven
Bake heater
Lower oven
Broil heater
Lower oven
Bake heater
Test procedures
1. Remove wire leads
2. Measure resistance after cooling down
1. Remove wire leads
2. Measure resistance after cooling down
1. Remove wire leads
2. Measure resistance after cooling down
4-3
Results
Normal : Approximately 26.6Ω
Abnomal : Infinite(opened)
NOTE: Ω Value was tested
at room temperature
(77F/25˚C)
Be careful the element is
sensitive to temperature.
Normal : Approximately 14.7Ω
Abnomal : Infinite(opened)
NOTE: Ω Value was tested
at room temperature
(77F/25˚C)
Be careful the element is
sensitive to temperature.
Normal : Approximately 22.4Ω
Abnomal : Infinite(opened)
NOTE: Ω Value was tested
at room temperature
(77F/25˚C)
Be careful the element is
sensitive to temperature.