Network Disconnection Tab - Monitoring The Connection Of A Specified Ip Address - Sony SNC-WR600 User Manual

Hide thumbs Also See for SNC-WR600:
Table of Contents

Advertisement

• Perform the following before setting the face
detection.
– Deselect the checkbox of Stabilizer in the
Installation tab of the System menu.
• An inactive area cannot be specified.
• A horizontal face (leaning too far sideways) cannot be
detected.
• Vertexes cannot be added or deleted. They are for
specifying a rectangular area only.
• When the privacy masking is used, the motion
detection function is not available for the mask areas.
Target Image
Select All PTZ position or Preset position.
All PTZ position
This is a common setting for the face detection settings
regardless of the camera PTZ position.
Preset position
You can set the face detection settings for each preset
position.
Selected preset
Displays the registered preset positions. Click a preset
position to position the camera, then make the face
detection settings for that position.
Detection area
Specify the effective scope of face detection. You can set
the area in the same way as the detection area setting in
VMD settings. (page 53)
A maximum of ten detection areas can be set. Similar to
the detection area setting in VMD settings, a trigger area
and vertexes can also be moved.
Detection sensitivity
Set the sensitivity of face detection. A value from 0 to 64
can be specified. Select low values to limit detection to
the human face, or high values to also detect subjects
that are similar the human face. This makes detection
easier when the subject is far from the camera.
Clicking Return to the default changes the value to the
default value.
Detection size
Specify the minimum and maximum size of face
detection. You can specify the size by specifying values
or by dragging vertexes to choose the area.
OK/Cancel
Click OK to finalize any changes made to the settings
and send them to the camera.
58
Setting the Sensor input/Camera tampering detection/Motion detection — Action input Menu
If you click Cancel, changes made to the settings will be
discarded and the screen will be reloaded with the
current camera settings.
Network disconnection Tab
— Monitoring the connection of a
specified IP address
Monitored IP address
Set the specific IP address of which the network
connection status is to be monitored.
IP address monitoring is not available for IPv6.
OK/Cancel
See "Buttons common to every menu" on page 21.