PERFORMANCE DATA
Cooling Capacity
LC249HV
Cooling Capacity Table for LC249HV (LCN249HV + LUU240HV)
Table 26: LCN249HV / LUU240HV Cooling Capacities.
Outdoor Air
Temp.
68 / 57
(°F DB)
TC
SHC
-4
22.61
18.08
-0.4
22.60
18.19
5
22.58
18.34
10
22.56
18.49
15
22.55
18.64
20
22.53
18.78
25
22.51
18.93
30
22.50
19.07
35
22.48
19.22
40
22.46
19.36
45
22.44
19.51
50
22.43
19.65
55
22.41
19.80
60
22.39
19.94
65
22.37
20.08
70
22.36
20.23
75
21.82
19.89
80
21.28
19.55
85
20.75
19.20
90
20.22
18.83
95
19.64
18.64
100
19.16
18.14
105
18.68
17.64
110
18.20
17.03
115
17.72
16.53
118
17.44
16.41
122
17.34
16.36
DB: Dry Bulb Temperature (°F)
WB: Wet Bulb Temperature (°F)
SHC: Sensible Capacity (kBtu/h)
PI: Power Input (kW) (includes compressor, indoor fan motor and
outdoor fan motor)
1. All capacities are net, evaporator fan motor heat is deducted.
2. Cooling range can be extended from 5°F down to -4°F using the Low Ambient Wind Baffle Kit (sold
separately).
3. Grey shading indicates reference data. When operating at this temperature, these values can be
different if the system is not running consistently.
52 | PERFORMANCE DATA
73 / 61
PI
TC
SHC
PI
TC
1.16
24.02
19.10
1.20
25.42
1.17
24.00
19.21
1.22
25.41
1.19
23.98
19.38
1.23
25.39
1.21
23.97
19.53
1.25
25.37
1.23
23.95
19.69
1.27
25.35
1.24
23.93
19.84
1.29
25.33
1.26
23.91
19.99
1.31
25.31
1.28
23.89
20.15
1.33
25.29
1.30
23.87
20.30
1.34
25.27
1.31
23.86
20.45
1.36
25.25
1.33
23.84
20.61
1.38
25.23
1.35
23.82
20.76
1.40
25.21
1.37
23.80
20.91
1.42
25.19
1.39
23.78
21.06
1.44
25.17
1.40
23.76
21.21
1.45
25.15
1.42
23.75
21.37
1.47
25.13
1.50
23.20
21.04
1.55
24.59
1.57
22.66
20.71
1.63
24.04
1.65
22.13
20.36
1.71
23.50
1.73
21.59
20.01
1.79
22.96
1.80
21.00
19.83
1.87
22.37
1.88
20.53
19.33
1.95
21.89
1.96
20.05
18.83
2.03
21.42
2.03
19.57
18.22
2.11
20.94
2.11
19.09
17.70
2.19
20.46
2.16
18.80
17.60
2.23
20.17
2.22
18.71
17.56
2.30
20.08
TC: Total Capacity (kBtu/h)
©
Indoor Air Temp. °F DB / °F WB
77 / 64
80 / 67
SHC
PI
TC
SHC
18.49
1.25
26.44
18.88
18.60
1.26
26.42
18.99
18.76
1.28
26.40
19.16
18.91
1.30
26.38
19.31
19.06
1.32
26.36
19.46
19.21
1.34
26.34
19.62
19.36
1.36
26.32
19.77
19.51
1.37
26.30
19.92
19.66
1.39
26.28
20.07
19.81
1.41
26.26
20.22
19.95
1.43
26.24
20.37
20.10
1.45
26.22
20.52
20.25
1.47
26.20
20.67
20.39
1.49
26.18
20.82
20.54
1.51
26.16
20.97
20.69
1.53
26.14
21.12
20.40
1.61
25.59
20.84
20.10
1.69
25.04
20.55
19.79
1.77
24.50
20.25
19.47
1.86
23.96
19.94
19.32
1.94
23.00
19.50
18.86
2.02
22.70
19.20
18.40
2.10
22.40
18.90
17.83
2.18
21.93
18.33
17.36
2.27
21.45
17.86
17.27
2.32
21.16
17.79
17.24
2.38
21.07
17.76
4. Direct interpolation is permissible.
Capacity as rated: 0 ft. above sea level with 24.6 ft. of refrigerant piping. 0 ft. level difference between
outdoor and indoor units.
Cooling capacity rating obtained with air entering the indoor unit at 80ºF dry bulb (DB) and 67ºF wet
bulb (WB), and outdoor ambient conditions of 95ºF dry bulb (DB) and 75ºF wet bulb (WB).
86 / 72
PI
TC
SHC
PI
TC
1.26
28.23
19.04
1.28
29.63
1.27
28.21
19.15
1.30
29.62
1.29
28.19
19.32
1.32
29.59
1.31
28.17
19.47
1.34
29.57
1.33
28.15
19.63
1.36
29.55
1.35
28.13
19.78
1.38
29.53
1.37
28.10
19.93
1.40
29.50
1.39
28.08
20.09
1.42
29.48
1.41
28.06
20.24
1.44
29.46
1.43
28.04
20.39
1.46
29.44
1.45
28.02
20.54
1.47
29.41
1.47
28.00
20.70
1.49
29.39
1.49
27.98
20.85
1.51
29.37
1.51
27.95
21.00
1.53
29.35
1.52
27.93
21.15
1.55
29.32
1.54
27.91
21.30
1.57
29.30
1.63
27.36
21.04
1.66
28.75
1.71
26.81
20.78
1.74
28.19
1.79
26.26
20.50
1.83
27.64
1.88
25.71
20.21
1.91
27.09
1.96
25.11
20.10
2.00
26.48
2.04
24.63
19.67
2.08
26.00
2.13
24.15
19.24
2.17
25.52
2.21
23.67
18.69
2.25
25.04
2.29
23.20
18.24
2.34
24.56
2.34
22.91
18.18
2.39
24.28
2.41
22.81
18.16
2.45
24.18
Do not extrapolate.
90 / 75
SHC
PI
19.40
1.31
19.52
1.32
19.69
1.35
19.84
1.37
20.00
1.39
20.16
1.41
20.31
1.43
20.47
1.44
20.62
1.46
20.78
1.48
20.93
1.50
21.09
1.52
21.24
1.54
21.40
1.56
21.55
1.58
21.70
1.60
21.46
1.69
21.21
1.78
20.94
1.86
20.67
1.95
20.58
2.04
20.15
2.12
19.73
2.21
19.19
2.30
18.75
2.38
18.70
2.43
18.69
2.50