3.
Avoid using the same power supply outlet for computers, telexes, and other office equipment.
Otherwise, Hybrid IP-PBX operation may be interrupted by the induction noise from such equipment.
4.
Please use 1-pair telephone wire for extension connection of (telephone) equipment such as standard
telephones, data terminals, answering machines, computers, Voice Processing Systems, etc., except
PTs (e.g., KX-T7600 series).
5.
The power switch of the Hybrid IP-PBX must be off during wiring. After the wiring is completed, turn the
power switch on.
6.
Mis-wiring may cause the Hybrid IP-PBX to operate improperly.
7.
If an extension does not operate properly, disconnect the telephone from the extension line and then
connect again, or turn the power to the Hybrid IP-PBX off and on again.
8.
The Hybrid IP-PBX is equipped with a 3-wire grounding type plug. This is a safety feature. If you are
unable to insert the plug into the outlet, contact your electrician to replace your obsolete outlet. Do not
defeat the purpose of the grounding-type plug.
9.
Use twisted pair cable for CO line connection.
10.
CO lines should be installed with surge protectors. For details, refer to "2.2.13 Surge Protector
Installation".
11.
To assure good quality telephone connection, it is recommended new and modifications to existing
installation of customer premise wiring shall use solid twisted pair copper conductors with minimum 24
gauge that comply with the electrical specifications for Category 3 wiring as detailed in ANSI/EIA/TIA-
570A Building Wiring Standards.