Connectable components
12.2 PP 72/48D PN and PP 72/48D 2/2A PN
Power loss
Output power X111, X222, X333:
Mechanical data
Dimensions WxHxD
Weight, approx.
Pollution degree
Heat dissipation/cooling
Condensation
Limitation of relative air humidity at
25 °C
Air pressure
Derating
Ambient temperature:
Storage
Shock load during transport (in
transport packaging)
For detailed technical data relating to the inputs and outputs, see the "Connecting" chapter.
X111, X222 and X333 pin assignment (Page 127)
Analog X3 inputs/outputs (Page 132)
144
Resistor
Pilot duty
Tungsten
Storage
Transport
Operation
24 V DC; 0.25 A/channel; 4 A/terminal
24 V DC; 0.25 A/channel; 4 A/terminal
150 x 300 x 35 mm
Open-circuit ventilation
Not permitted
5 to 95% (without condensation)
5 to 90% (with condensation)
106 to 92 kPa or
0 to 1000 m above mean sea level
At installation altitudes of more than 1000 to 4000 m above mean
sea level, the upper temperature limit must be reduced by
3.5 °C / 500 m.
1M2 (in product package); 1.5 mm; 0.5 g
Free-fall ≤ 1 m
Equipment Manual, 09/2022, A5E51087503B AC
18 W
24 V; 5 W
0.9 kg
2
-40 to 70 °C
-40 to 70 °C
0 to 55 °C