Malfunction
The cartridge strip melts
A cartridge detaches itself
from the cartridge strip
10
Disposal
Most of the materials from which Hiltiproducts are manufactured can be recycled. The materials must be
correctly separated before they can be recycled. In many countries, your old tools, machines or appliances
can be returned to Hilti for recycling. Ask Hilti Service or your Hilti representative for further information.
11
Manufacturer's warranty
▶ Please contact your local Hilti representative if you have questions about the warranty conditions.
12
C.I.P. test confirmation
The following applies to C.I.P. member states outside the EU and EFTA judicial areas: The Hilti DX 351 BT
and DX 351 BTG has been system and type tested. As a result, the tool bears the rectangular PTB approval
mark showing approval number S 807. Hilti thus guarantees compliance with the approved type.
13

Further information

For more information on operation,
qr.hilti.com/manual/?id=3377625&id=377626&id=377627&id=377628
This link is also to be found at the end of the operating instructions, in the form of a QR code.

Originele handleiding

1
Informatie over de handleiding
1.1
Bij deze handleiding
Lees voor ingebruikname deze handleiding door. Dit is vereist voor veilig werken en storingsvrij gebruik.
De veiligheidsinstructies en waarschuwingsaanwijzingen in deze handleiding en op het product in acht
nemen.
De handleiding altijd bij het product bewaren en het product alleen met deze handleiding aan andere
personen doorgeven.
30
Nederlands
Possible cause
Fastening tool was pressed against
the working surface for too long.
Fastener driving rate too high (fas-
tening tool overheated).
Fastener driving rate too high (fas-
tening tool overheated).
technology,
environment and recycling,
Action to be taken
▶ Remove cartridge strip and
insert a new cartridge strip
instead.
▶ Fire the fastening tool sooner
after pressing it against the
working surface.
▶ Stop using the tool immediately.
▶ Remove cartridge strips and
allow the fastening tool to cool
down.
▶ Do not exceed the recom-
mended maximum fastener
driving rate (see the section
headed "Technical data").
▶ Stop using the tool immediately.
▶ Remove cartridge strips and
allow the fastening tool to cool
down.
▶ Do not exceed the recom-
mended maximum fastener
driving rate (see the section
headed "Technical data").