13.

Problems and solutions

Fault
Steam leaks from the accessories
Steam tube plug is difficult to insert
into the outlet of the machine
The boiler needs more time to warm up. Clean the boiler as described. In case, make
Pressure drops quickly while using the
steam
Intervention of the circuit breaker
during use. (Probable dispersion from
the resistance or electric valve to
ground)
Solution
due to wear or damage of o-rings. Replace
them taking care not to damage them and
insert them with attention
Do not force to insert it, but put a bit of
silicone lubricant on the o-rings and into the
joint connection.
the absorption with the power rating
indicated in the technical data check.
It is due to limestone, clean the boiler as
described.
Check that the power cord is not visibly
damaged. Try connecting the plug into a
different socket. Verify that there are no
spills or leakage of water from the machine,
in this case have it checked by a qualified
center.