Pressure Transducer; Suction Tube - Graco LineLazer 3000 Instructions-Parts List Manual

Gasoline-powered airless linestriper
Hide thumbs Also See for LineLazer 3000:
Table of Contents

Advertisement

WARNING
INJECTION HAZARD
To reduce the risk of serious injury,
whenever you are instructed to relieve
pressure, follow the Pressure Relief
Procedure on page 17.
NOTE: See Fig. 12 for this procedure.
1. Remove the displacement pump. See page 35.
2. Use a pull–twist motion to remove the transducer
(22) from the pump manifold.
3. Clean paint residue from the hole in the manifold;
do not scratch the surface of the hole.
4. Lightly apply oil to the o-ring of the new transducer.
5. Install the transducer in the pump manifold, while
guiding the o-ring and backup ring into place.
6. Align the holes in the transducer as shown by the
arrows in Fig. 12.
7. Install the displacement pump. See page 36.
WARNING
INJECTION HAZARD
To reduce the risk of serious injury,
whenever you are instructed to relieve
pressure, follow the Pressure Relief
Procedure on page 17.
1. Put a wrench on the fitting (47) and another on the

suction tube (39).

2. Unscrew the suction tube (39) from the fitting.
CAUTION
Misaligning or cross-threading the suction tube to the
fitting may damage the threads and/or create shav-
ings causing the fitting and/or suction tube to leak.

Pressure Transducer

Suction Tube
22
Fig. 12
47
39
Fig. 13
06925B
06926B
308685
25