COMPONENT ACCESS (Cont.)
6. Pull the wire harness connector off the cold water inlet valve.
A
B
A. Wire for Hot Water Inlet Valve
B. Wire for Cold water inlet Valve
NOTE: Wires for the inlet valves are color coded, red and
white wires for the hot water inlet valve, blue and white wires
for the cold water inlet valve.
7. Remove two T-20 screws securing the water inlet assembly to
the top of washer.
Thermistor
1. Complete the
steps 1-10
2. Remove the Power Cord.
3. Remove Water Inlet Valve.
4. Release the tabs and remove the thermistor from the top of
the vacuum break.
NOTE: The thermistor is part of the wire harness for the
water inlet valves.
4-4
Maytag
3.5 cu.ft. Commercial-Grade Residential Agitator Washer
n
®
from Panels removal instructions.
Motor Relay
1. Complete the
steps 1-10
2. Remove the Power cord.
3. Remove the Water Inlet Valve and Thermistor.
4. Slide the motor relay out from under the screw and remove it
from the console.
5. Loosen one, and remove the other, 5/16" (8mm) hex head
screw securing the motor relay to the top of the washer.
6. Pull the plug off the spade connectors on the top of the
motor relay.
Transformer
1. Complete the
steps 1-10
2. Remove the Power Cord.
3. Remove the Water Inlet Valve and Thermistor.
4. Remove the Motor Relay.
5. Remove two 5/16" or (8mm) hex head screws securing the
transformer to the top of the washer.
from Panels removal instructions.