Change settings on the OTHER OPTIONS menu
by highlighting the desired line using the UP/
DOWN buttons and using the +/– buttons to
step through the available settings. To return
to the MAIN menu, press the ENTER button.
Press the MENU/OSD button on the remote
to cancel the display and return to normal
operation.

Zone 2 Setup

ZONE2 SETUP
SOURCE:Off
VOLUME SETUP:Variable
VOLUME:60
TURN ON VOL:Last
MAX VOL:Max
12V TRIGGER:Off
MAIN MENU
The ZONE 2 SETUP menu provides settings
and configuration options related to the op-
eration of Zone 2. This menu is reached by
highlighting the ZONE 2 line on the MAIN
menu and pressing ENTER.
SOURCE: Specifies a source for listening in
Zone 2. Options are CD, TUNER, TAPE, VIDEO
1–5, SOURCE, and OFF. Selecting the
SOURCE option links the Zone 2 source to the
source selected for the main zone so that Zone
2 will hear the same source as the main zone.
Selecting the OFF option turns Zone 2 off.
VOLUME SETUP: configures the Zone 2
outputs for VARIABLE or FIXED volume levels.
VARIABLE allows control of the volume settings
in Zone 2 from the RSP-1068 front panel or
from a remote control/IR repeater in Zone 2.
FIXED output disables the Zone 2 volume
control. In this mode, the Zone 2 level can be
fixed at the level specified on the next line,
thus optimizing system performance when send-
ing a fixed level signal to a preamp or ampli-
fier with its own volume adjustment.
VOLUME: In VARIABLE output mode, this line
shows the current volume setting for Zone 2.
In FIXED output mode, this volume setting es-
tablishes a permanent fixed output level for
Zone 2.
Move the highlight to the desired line using
the UP/DOWN buttons and use the +/– but-
tons to adjust the volume level. To return to the
MAIN menu, press the ENTER button. Press
the MENU/OSD button on the remote to cancel
the display and return to normal operation.
TURN ON VOL: Specifies a default volume
level to be used each time Zone 2 is activated.
You can select LAST to have Zone 2 activate
with the last previously used volume setting.
Or, you specify a volume from MIN (full mute)
to MAX, in 1dB increments. Note that this setting
cannot exceed the MAX VOL established in
the next line of the menu.
MAX VOL: Specifies the maximum volume
level for Zone 2. The volume cannot be ad-
justed above this level. Settings range from MIN
to MAX, in 1dB increments.
12V TRIGGER: The 12V trigger labeled
ZONE 2 can be assigned to sources selected
from Zone 2 and will send a turn-on signal
whenever Zone 2 is activated for that source.
Select the ON setting for each source to have
the ZONE 2 trigger output send the turn-on
signal. Select the OFF setting to disable the
12V trigger function for each source in Zone
2.
: From the factory, all 12V triggers are
NOTE
set to ON, including Zone 2 SOURCE:Off.

Default Setup

DEFAULT SETUP
FACTORY DEFAULT:No
USER DEFAULT:No
SET USER DEFAULT:No
MAIN MENU
The DEFAULT SETUP menu provides access to
three functions:
• Restore all features and settings to the origi-
nal FACTORY DEFAULT settings.
• Memorize a custom group of settings as
a USER DEFAULT.
• Activate the memorized USER DEFAULT set-
tings.
To restore the FACTORY DEFAULT set-
tings: Place the highlight on the FACTORY
DEFAULT line using the UP/DOWN buttons
and use the +/– buttons to change the setting
to YES. Press the ENTER button to proceed with
resetting the FACTORY DEFAULT settings. The
unit will power off and then on, with the fac-
tory settings restored. To return to the MAIN
40
menu without resetting the FACTORY DEFAULT
settings, change the entry to NO and press
the ENTER button.
: Resetting to factory default settings will
NOTE
erase all stored settings including delay set-
tings, speaker settings, balance settings, in-
put settings and more. You will lose ALL system
configuration settings. Be certain that you wish
to do so before resetting the factory defaults.
To memorize USER DEFAULT settings:
Many of the current configuration settings can
be stored as a USER DEFAULT, which can be
activated at any time from this menu screen.
To save the current settings as a USER DEFAULT,
place the highlight on the SET USER DEFAULT
line using the UP/DOWN buttons and use the
+/– buttons to change the setting to YES. Press
the ENTER button to store the new USER DE-
FAULT settings. To return to the MAIN menu
without saving any changes, change all en-
tries on the screen to NO and press the EN-
TER button.
: If there is insufficient memory to store a
NOTE
USER DEFAULT configuration file, the SET
USER DEFAULT option will not be available.
To activate memorized USER DEFAULT
settings: After you have stored a USER DE-
FAULT configuration file, you can activate those
settings at any time by placing the highlight
on the USER DEFAULT line using the UP/
DOWN buttons. Use the +/– buttons to change
the setting to YES. Press the ENTER button to
proceed with activating the USER DEFAULT
settings. To return to the MAIN menu without
activating the USER DEFAULT settings, change
the entry to NO and press the ENTER button.